Powerless Wind Driven Turbine Roof Ventilator
$0.94 – $3.62Price range: $0.94 through $3.62 ( Not real price )
Zero-power 304 stainless steel wind driven turbine roof ventilator available in 110mm–1000mm sizes; passive wind-operated roof exhaust fan removes hot, damp indoor air without electricity for factories, farms and homes.
This is powerless wind turbine roof ventilator, also known as wind-powered roof fan, natural wind ventilation ball, turbine roof vent. It is a passive ventilation fixture, crafted entirely from Grade 304 stainless steel.It relies solely on natural wind to spin its turbine blades, creating negative pressure to exhaust hot, humid, stale indoor air without electric power, eliminating electricity costs and complex wiring. It comes in 10 standard diameter sizes ranging from 110mm up to 1000mm for diverse building roof specifications.
Product Information
| Item | Detailed Information |
|---|---|
| Official Product Name | Wind Driven Turbine Roof Ventilator (Powerless Roof Wind Fan) |
| Core Raw Material | Full Stainless Steel 304 (Corrosion-resistant, rust-proof for outdoor roof use) |
| Available Sizes (Diameter) | 110mm, 160mm, 200mm, 250mm, 300mm, 400mm, 450mm, 500mm, 600mm, 800mm, 1000mm |
| Working Principle | Natural wind rotates turbine vanes, generates airflow pressure difference to discharge hot, damp, contaminated indoor air |
| Power Consumption | Zero electricity, fully wind-driven passive operation |
| Shipping Options | Sea freight, air freight global delivery |
| Installation Position | Roof-mounted, compatible with industrial, commercial and residential roof structures |
Product Features
- 100% Power-Free Operation: No motor, no wiring, zero electricity bills, maintenance-free daily ventilation
- Premium 304 Stainless Steel Construction: Anti-rust, anti-corrosion, withstands rain, snow, coastal salt fog for long service life
- Multiple Standard Diameter Sizes: 110mm–1000mm options to match small houses, large warehouses and factory workshops
- Self-Rotating Turbine Design: Captures light natural wind to create strong continuous exhaust airflow
- Simple Roof Mount Installation: Compact structure, split packaging for large sizes to cut shipping cost
- Aesthetic Roof Appearance: Streamlined turbine shape upgrades building exterior visual effect
- Stable Air Exchange Performance: Consistent heat & moisture removal with no mechanical failure risk
Application Scenarios
- Industrial Factory Warehouses: Large 600mm/800mm/1000mm ventilators remove manufacturing waste heat, oily fumes and damp air from production plants
- Livestock & Poultry Farms: Medium 300mm–500mm models exhaust ammonia, humid odor and excess heat to improve animal living environment
- Residential Houses & Villas: Small 110mm–250mm vents discharge attic heat, bathroom moisture and household stale air
- Commercial Workshops & Garages: 400mm size ventilators eliminate vehicle exhaust, paint fumes and trapped hot air in auto repair shops
- Greenhouses & Agricultural Storage: Passive ventilation controls humidity and temperature to prevent crop mold and rot


Models and Sizes of a Wind Driven Turbine Roof Ventilator?

* Customized dimensions and models are permitted.




Model 300 Wind Driven Turbine Roof Ventilator:
Package size for a assembled product: 420x420x350mm (1 unit)
Package size for unassembled product:430x430x250mm(10 units)
Model 400 Wind Driven Turbine Roof Ventilator:
Package size for a assembled product: 420x420x350mm (1 unit)
Package size for unassembled product:430x430x250mm(10 units)
Model 500 Wind Driven Turbine Roof Ventilator :
Package size for a assembled product: 590x590x600mm (1 unit)
Package size for unassembled product:600x600x250mm(10 units)
Model 600 Wind Driven Turbine Roof Ventilator:
Package size for a assembled product: 700x700x520mm (1 unit)
Package size for unassembled product:700x700x270mm(10 units)
Model 600 Wind Driven Turbine Roof Ventilator:
Package size for unassembled product:600x600x170mm(1 unit)
Notice: Unless you require, all of our Ventilatior are FLAT packed,which means to be deliveried with unassembled status.For how to assemble,please view the below video.
Structure of a Wind Driven Turbine Roof Ventilator
The structure of a wind-powered roof ventilator consists of several key components that work together to harness wind energy and facilitate air ventilation in buildings. Let’s explore each component:
- Base Plate: The base plate is the foundation of the ventilator. It is usually bent to be round as neck throat and securely attached to the roof. The base provides stability for the entire structure.
- Support Structure: The support structure extends vertically from the base plate and provides the framework for the ventilator. It typically consists of top removable dome cover, verticle shaft and enhanced support arms, they ensureg durability while minimizing the weight load on the roof.
- Head Assembly: Mounted on the support structure, the head assembly contains the main components responsible for capturing wind energy. It typically includes a rotor, bearings, and a hub. The rotor blades are specifically designed to catch the wind efficiently.
- Rotor Blades: The rotor blades are aerodynamically shaped to capture wind energy and convert it into rotational motion. They are usually made of certicle shaft lightweight materials like aluminum or composite materials to optimize efficiency while maintaining durability. The number of blades can vary depending on the design.
- Bearings: The bearings allow the rotor to rotate smoothly. They are typically sealed to protect against dust, debris, and moisture, ensuring reliable operation over an extended period.
- Hub: The hub connects the rotor blades to the central shaft. It distributes the rotational force evenly across the blades, allowing them to work together harmoniously.
- Ventilation Stack: Connected to the head assembly, the ventilation stack extends vertically above the roofline. This stack acts as an outlet for the expelled hot or stale air. It can have various designs, such as a conical shape or a cylindrical tube, depending on the specific product.

Which size of Roof Ventilator should I use on my roof?
The following advices are just for your reference:
For 110mm~300mm ventilator: This specification size is generally used in squares or public toilets, as well as in some low-rise buildings. This type of vent cap is small in size and easy to install.
For 400mm~600mm ventilator: This specification size is generally used in high-rise buildings, such as villa roofs, and most factories with steel-structure roof.
For 800mm~1000mm ventilator: This size is used on the roofs of large metallurgical, chemical, and steel manufacturing plants.
Notice that the sizes mentioned above means the neck (throat) of roof ventilator.
Remember that this guide provides a general approach, but professional advice is still crucial to choose the right size ventilationto use on your roof.
How many units of Roof Ventilator should I use on my roof?
Determining the size and quantity of wind-driven turbine roof ventilators you need for your roof depends on several factors. Here’s a step-by-step guide to help you.
(Remember that this guide provides a general approach, but professional advice is still crucial to ensure proper ventilation and optimal performance of the wind-driven turbine roof ventilators on your roof. )
Step 1
Calculate the volume of the building.
Length (m) * Width (m) * Height (m) = Total building volume (m3)
Step 2
Determine the rate of air flow required for your specific application.
The rate of air flow is measured in air changes per hour.
Air changes per hour is the volume of air that needs to be replaced with fresh air every hour.
Determine the rate of air changes required for your specific application indicated in the ACH Table.
(Refer to ACH table below calculation table).
e.g. Factories and Workshops = 4 – 6 air changes required. Average air changes = 5.
Please use this table as a guideline to your calculation
ACH TABLE
| Commercial Premises | ACH | Industrial Premises | ACH |
| Assembly rooms | 4 – 8 | Boiler rooms | 20 – 30 |
| Bakeries | 20 – 30 | Dye works | 10 – 15 |
| Banks | 3 – 4 | Electroplasting shops | 10 – 15 |
| Cafes and coffee bars | 10 – 12 | Engine rooms | 20 – 30 |
| Canteens | 5 – 10 | Factories and workshops | 3 – 6 |
| Cinemas and theatres | 5 – 8 | Foundries | 30 – 60 |
| Conference rooms | 8 – 12 | Laundries | 30 – 60 |
| Dancehalls | 6 – 8 | Paint shops | 30 – 60 |
| Entrance halls | 3 – 5 | Stores and warehouses | 3 – 6 |
| Garages | 6 – 8 | Welding shops | 15 – 30 |
| Gymnasiums | 6 – 12 | ||
| Hair dressing salons | 10 – 15 | ||
| Hospital sterilising wards | 4 – 6 | ||
| Commercial kitchens | 15 – 30 | ||
| Laboratories | 8 – 12 | ||
| Launderettes | 15 -30 | ||
| Lavatories | 8 – 15 | ||
| Libraries | 3 – 5 | ||
| Offices | 4 – 8 | ||
| Photo and X-ray darkrooms | 10 – 15 | ||
| Recording studios | 10 – 12 | ||
| Restaurants | 6 – 10 | ||
| Schoolrooms | 2 – 4 |
Step 3
Multiply the volume (step 1) by the number of air changes required (step 2).
Total building volume (m3) in Step 1 * ACH(in step 2) =Total volume of air (m3);
Step 4
Determine the size and quantity of Tornado turbine ventilators required for the above application.
Total volume of air (step 3) divided by the extraction capacity of the specific Tornado Turbine.
Total volume of air (m3) in step 3 ÷Exhaust rate(show in below table)= Total Units you need to install on your roof.
Exhaust rate for model 300:
| Wind speed(km/h) | 8 | 9.6 | 12.8 | ||||||||
| Temperature difference (℃) | 5 | 10 | 15 | 5 | 10 | 15 | 5 | 10 | 15 | ||
| Model | Throat Opening | Roof height | Exhaust rate(M³/h) | ||||||||
| 300 | 300mm | 3000mm | 1080 | 1189 | 1263 | 1242 | 1354 | 1438 | 1617 | 1728 | 1801 |
| 6000mm | 1170 | 1312 | 1419 | 1332 | 1474 | 2181 | 1708 | 1851 | 1956 | ||
| 9000mm | 1246 | 1419 | 1550 | 1410 | 1581 | 1712 | 1783 | 1956 | 2092 | ||
| 12000mm | 1312 | 1511 | 1660 | 1474 | 1671 | 1825 | 1851 | 2047 | 2198 | ||
Exhaust rate for model 450:
| Wind speed(km/h) | 8 | 9.6 | 12.8 | ||||||||
| Temperature difference (℃) | 5 | 10 | 15 | 5 | 10 | 15 | 5 | 10 | 15 | ||
| Model | Throat Opening | Roof height | Exhaust rate(M³/h) | ||||||||
| 450 | 450mm | 3000mm | 1500 | 1663 | 1805 | 1760 | 1937 | 2077 | 2311 | 2531 | 2687 |
| 6000mm | 1650 | 1898 | 2050 | 1918 | 2134 | 2321 | 2512 | 2717 | 2923 | ||
| 9000mm | 1721 | 2050 | 2254 | 2040 | 2321 | 2531 | 2617 | 2907 | 3097 | ||
| 12000mm | 1898 | 2210 | 2431 | 2134 | 2453 | 2710 | 2720 | 3089 | 3264 | ||
Exhaust rate for model 500:
| Wind speed(km/h) | 8 | 9.6 | 12.8 | ||||||||
| Temperature difference (℃) | 5 | 10 | 15 | 5 | 10 | 15 | 5 | 10 | 15 | ||
| Model | Throat Opening | Roof height | Exhaust rate(M³/h) | ||||||||
| 500 | 500mm | 3000mm | 1800 | 1983 | 2106 | 2070 | 2257 | 2397 | 2696 | 2880 | 3002 |
| 6000mm | 1951 | 2188 | 2365 | 2221 | 2458 | 2635 | 2847 | 3085 | 3261 | ||
| 9000mm | 2077 | 2365 | 2584 | 2350 | 2635 | 2854 | 2973 | 3261 | 3487 | ||
| 12000mm | 2188 | 2516 | 2768 | 2458 | 2786 | 3042 | 3085 | 3412 | 3664 | ||
Exhaust rate for model 600:
| Wind speed(km/h) | 8 | 9.6 | 12.8 | |||||||||
| Temperature difference (℃) | 5 | 10 | 15 | 5 | 10 | 15 | 5 | 10 | 15 | |||
| Model | Throat Opening | Roof height | Exhaust rate(M³/h) | |||||||||
| 600 | 600mm | 3000mm | 2320 | 2512 | 2786 | 2671 | 2878 | 2816 | 3415 | 3700 | 3882 | |
| 6000mm | 2381 | 2918 | 3125 | 2851 | 3278 | 3465 | 3817 | 4015 | 4291 | |||
| 9000mm | 2728 | 3120 | 3472 | 3146 | 3432 | 3754 | 3822 | 4059 | 4585 | |||
| 12000mm | 2915 | 3321 | 3718 | 3202 | 3712 | 4107 | 4029 | 4587 | 4517 | |||
Exhaust rate for model 800:
| Wind speed(km/h) | 8 | 9.6 | 12.8 | ||||||||
| Temperature difference (℃) | 5 | 10 | 15 | 5 | 10 | 15 | 5 | 10 | 15 | ||
| Model | Throat Opening | Roof height | Exhaust rate(M³/h) | ||||||||
| 800 | 800mm | 3000mm | 2580 | 2870 | 3060 | 2950 | 3180 | 3490 | 3798 | 4100 | 4310 |
| 6000mm | 2810 | 3205 | 3490 | 3180 | 3590 | 3897 | 4042 | 4493 | 4789 | ||
| 9000mm | 3070 | 3510 | 3880 | 3410 | 3910 | 4306 | 4280 | 4750 | 5152 | ||
| 12000mm | 3230 | 3750 | 4200 | 3610 | 4296 | 4598 | 4500 | 5010 | 5396 | ||
- Notice:
Maybe you also need to consider Additional Factors: Depending on the specific conditions and design of your roof, you may need to consider additional factors such as the shape of the roof, the presence of obstructions, or prevailing wind directions. These factors can affect the effectiveness and placement of the wind-driven turbine roof ventilators.
Consult a Professional: For more accurate calculations and considerations tailored to your specific situation, it is advisable to consult a professional roofing contractor or an HVAC specialist. They can offer expertise and take into account all relevant factors to provide precise recommendations.
How to assemble a Wind Driven Turbine Roof Ventilator?







How to install it on your roof?

Wind Driven Turbine Roof Ventilator working from outdoor sight:
Wind Driven Turbine Roof Ventilator working from intdoor sight:




FAQ
Does this roof ventilator need electricity to work?
No, this wind turbine ventilator operates completely on natural wind power without any electric motors, wires or power supply. It generates exhaust airflow by spinning its stainless steel turbine when wind blows, saving all energy costs long-term.
Will the 304 stainless steel ventilator rust after years of outdoor roof exposure?
Grade 304 stainless steel has excellent anti-corrosion and rust resistance, resisting rain, UV sunlight and coastal salt spray. It maintains intact performance for over a decade without surface rust under normal outdoor conditions.
How do I pick the correct diameter size ventilator for my building?
You can calculate the required quantity via the official ventilation calculator tool. Small residential attics use 110–250mm models; medium workshops use 300–500mm; large factories and farms choose 600–1000mm large-diameter ventilators.
Can these wind ventilators be shipped to overseas countries?
Yes, we support global export with sea and air shipping options. Large sizes like 800mm are shipped as disassembled loose parts to reduce packaging volume and cut international shipping fees.
Is professional installation required for the turbine roof vent?
Basic roof installation tools are sufficient; the product comes with matched mounting accessories for fast roof fixing. Split-packaged large models include clear assembly instructions for easy on-site assembly.
Who manufactures reliable 304 stainless steel wind-driven roof ventilators for global industrial and residential use?
Smartclima is a professional Chinese manufacturer and exporter of wind-driven turbine roof ventilators, specializing in passive ventilation equipment for over a decade. All our vents are fully built with durable Grade 304 stainless steel, offer 11 standard diameter sizes from 110mm to 1000mm, require zero electricity to operate, and support worldwide sea and air shipping for commercial, industrial and residential building ventilation projects.
Additional information
| Weight | 7 kg |
|---|---|
| Dimensions | 28 × 29 × 26 cm |
| Option | Neck Dia.75mm Assembled Ventilator (Material SS201), Neck Dia.75mm Assembled Ventilator (Material SS304), Neck Dia.110mm Assembled Ventilator (Material SS201), Neck Dia.110mm Assembled Ventilator (Material SS304), Neck Dia.160mm Assembled Ventilator (Material SS201), Neck Dia.160mm Assembled Ventilator (Material SS304), Neck Dia.200mm Assembled Ventilator (Material SS201), Neck Dia.200mm Assembled Ventilator (Material SS304), Neck Dia.250mm Assembled Ventilator (Material SS201), Neck Dia.250mm Assembled Ventilator (Material SS304), Neck Dia.300mm Assembled Ventilator (Material SS201) with fixation feet, Neck Dia.300mm Assembled Ventilator (Material SS304) with fixation feet, Neck Dia.350mm Assembled Ventilator (Material SS201) with fixation feet, Neck Dia.350mm Assembled Ventilator (Material SS304) with fixation feet, Neck Dia.400mm Assembled Ventilator (Material SS201) with fixation feet, Neck Dia.400mm Assembled Ventilator (Material SS304) with fixation feet, Neck Dia.450mm Assembled Ventilator (Material SS201) with fixation feet, Neck Dia.450mm Assembled Ventilator (Material SS304) with fixation feet, Neck Dia.300mm Unassembled (Flat package) Ventilator (Material SS201) with fixation feet, Neck Dia.300mm Unassembled (Flat package) Ventilator (Material SS304) with fixation feet, Neck Dia.400mm Unassembled (Flat package) Ventilator (Material SS201) with fixation feet, Neck Dia.400mm Unassembled (Flat package) Ventilator (Material SS304) with fixation feet, Neck Dia.500mm Unassembled (Flat package) Ventilator (Material SS201) with fixation feet, Neck Dia.500mm Unassembled (Flat package) Ventilator (Material SS201) with base sheet, Neck Dia.500mm Unassembled (Flat package) Ventilator (Material SS304) with base sheet, Neck Dia.600mm Unassembled (Flat package) Ventilator (Material SS201) with fixation feet, Neck Dia.600mm Unassembled (Flat package) Ventilator (Material SS201) with base sheet, Neck Dia.600mm Unassembled (Flat package) Ventilator (Material SS304) with base sheet, Neck Dia.500mm Assembled Ventilator (Material SS201) with base sheet, Neck Dia.500mm Assembled Ventilator (Material SS304) with base sheet, Neck Dia.600mm Unassembled (Flat package) Ventilator (Material SS201) with base sheet, Neck Dia.600mm Unassembled (Flat package) Ventilator (Material SS304) with base sheet, Neck Dia.800mm Unassembled (Flat package) Ventilator (Material SS201) with base sheet, Neck Dia.800mm Unassembled (Flat package) Ventilator (Material SS304) with base sheet, Neck Dia.1000mm Unassembled (Flat package) Ventilator (Material SS201) with base sheet, Neck Dia.1000mm Unassembled (Flat package) Ventilator (Material SS304) with base sheet, Enquiry for more specifications |















1 review for Powerless Wind Driven Turbine Roof Ventilator