Zero-power 304 stainless steel wind driven turbine roof ventilator available in 110mm–1000mm sizes; passive wind-operated roof exhaust fan removes hot, damp indoor air without electricity for factories, farms and homes.

GTIN: 16204000820748 SKU: SC18061656 Category:
Our products are liked and shared by:

This is powerless wind turbine roof ventilator, also known as wind-powered roof fan, natural wind ventilation ball, turbine roof vent. It is a passive ventilation fixture, crafted entirely from Grade 304 stainless steel.It relies solely on natural wind to spin its turbine blades, creating negative pressure to exhaust hot, humid, stale indoor air without electric power, eliminating electricity costs and complex wiring. It comes in 10 standard diameter sizes ranging from 110mm up to 1000mm for diverse building roof specifications.

Product Information

ItemDetailed Information
Official Product NameWind Driven Turbine Roof Ventilator (Powerless Roof Wind Fan)
Core Raw MaterialFull Stainless Steel 304 (Corrosion-resistant, rust-proof for outdoor roof use)
Available Sizes (Diameter)110mm, 160mm, 200mm, 250mm, 300mm, 400mm, 450mm, 500mm, 600mm, 800mm, 1000mm
Working PrincipleNatural wind rotates turbine vanes, generates airflow pressure difference to discharge hot, damp, contaminated indoor air
Power ConsumptionZero electricity, fully wind-driven passive operation
Shipping OptionsSea freight, air freight global delivery
Installation PositionRoof-mounted, compatible with industrial, commercial and residential roof structures

Product Features

  1. 100% Power-Free Operation: No motor, no wiring, zero electricity bills, maintenance-free daily ventilation
  2. Premium 304 Stainless Steel Construction: Anti-rust, anti-corrosion, withstands rain, snow, coastal salt fog for long service life
  3. Multiple Standard Diameter Sizes: 110mm–1000mm options to match small houses, large warehouses and factory workshops
  4. Self-Rotating Turbine Design: Captures light natural wind to create strong continuous exhaust airflow
  5. Simple Roof Mount Installation: Compact structure, split packaging for large sizes to cut shipping cost
  6. Aesthetic Roof Appearance: Streamlined turbine shape upgrades building exterior visual effect
  7. Stable Air Exchange Performance: Consistent heat & moisture removal with no mechanical failure risk

Application Scenarios

  1. Industrial Factory Warehouses: Large 600mm/800mm/1000mm ventilators remove manufacturing waste heat, oily fumes and damp air from production plants
  2. Livestock & Poultry Farms: Medium 300mm–500mm models exhaust ammonia, humid odor and excess heat to improve animal living environment
  3. Residential Houses & Villas: Small 110mm–250mm vents discharge attic heat, bathroom moisture and household stale air
  4. Commercial Workshops & Garages: 400mm size ventilators eliminate vehicle exhaust, paint fumes and trapped hot air in auto repair shops
  5. Greenhouses & Agricultural Storage: Passive ventilation controls humidity and temperature to prevent crop mold and rot
Wind Driven Turbine Roof Ventilator
All Wind Driven Turbine Roof Ventilators

Models and Sizes of a Wind Driven Turbine Roof Ventilator?

dimension of Wind Driven Turbine Roof Ventilator

* Customized dimensions and models are permitted.

different installation method for different Wind Driven Turbine Roof Ventilator

small throat diameter roof ventilator

Medium size roof ventilator

big throat roof ventilator and its cover adapter

Model 300 Wind Driven Turbine Roof Ventilator:
Package size for a assembled product: 420x420x350mm (1 unit)
Package size for unassembled product:430x430x250mm(10 units)

Model 400 Wind Driven Turbine Roof Ventilator:
Package size for a assembled product: 420x420x350mm (1 unit)
Package size for unassembled product:430x430x250mm(10 units)

Model 500 Wind Driven Turbine Roof Ventilator :
Package size for a assembled product: 590x590x600mm (1 unit)
Package size for unassembled product:600x600x250mm(10 units)

Model 600 Wind Driven Turbine Roof Ventilator:
Package size for a assembled product: 700x700x520mm (1 unit)
Package size for unassembled product:700x700x270mm(10 units)

Model 600 Wind Driven Turbine Roof Ventilator:
Package size for unassembled product:600x600x170mm(1 unit)

Notice: Unless you require, all of our Ventilatior are FLAT packed,which means to be deliveried with unassembled status.For how to assemble,please view the below video.

Structure of a Wind Driven Turbine Roof Ventilator

The structure of a wind-powered roof ventilator consists of several key components that work together to harness wind energy and facilitate air ventilation in buildings. Let’s explore each component:

  1. Base Plate: The base plate is the foundation of the ventilator. It is usually bent to be round as neck throat and securely attached to the roof. The base provides stability for the entire structure.
  2. Support Structure: The support structure extends vertically from the base plate and provides the framework for the ventilator. It typically consists of top removable dome cover, verticle shaft and enhanced support arms,  they ensureg durability while minimizing the weight load on the roof.
  3. Head Assembly: Mounted on the support structure, the head assembly contains the main components responsible for capturing wind energy. It typically includes a rotor, bearings, and a hub. The rotor blades are specifically designed to catch the wind efficiently.
  4. Rotor Blades: The rotor blades are aerodynamically shaped to capture wind energy and convert it into rotational motion. They are usually made of certicle shaft lightweight materials like aluminum or composite materials to optimize efficiency while maintaining durability. The number of blades can vary depending on the design.
  5. Bearings: The bearings allow the rotor to rotate smoothly. They are typically sealed to protect against dust, debris, and moisture, ensuring reliable operation over an extended period.
  6. Hub: The hub connects the rotor blades to the central shaft. It distributes the rotational force evenly across the blades, allowing them to work together harmoniously.
  7. Ventilation Stack: Connected to the head assembly, the ventilation stack extends vertically above the roofline. This stack acts as an outlet for the expelled hot or stale air. It can have various designs, such as a conical shape or a cylindrical tube, depending on the specific product.
structure of a wind powered roof ventilator

Which size of Roof Ventilator should I use on my roof?

The following advices are just for your reference:

For 110mm~300mm ventilator: This specification size is generally used in squares or public toilets, as well as in some low-rise buildings. This type of vent cap is small in size and easy to install.

For 400mm~600mm ventilator: This specification size is generally used in high-rise buildings, such as villa roofs, and most factories with steel-structure roof.

For 800mm~1000mm ventilator: This size is used on the roofs of large metallurgical, chemical, and steel manufacturing plants.

Notice that the sizes mentioned above means the neck (throat) of roof ventilator.

Remember that this guide provides a general approach, but professional advice is still crucial to choose the right size ventilationto use on your roof.

How many units of Roof Ventilator should I use on my roof?

Determining the size and quantity of wind-driven turbine roof ventilators you need for your roof depends on several factors. Here’s a step-by-step guide to help you.

(Remember that this guide provides a general approach, but professional advice is still crucial to ensure proper ventilation and optimal performance of the wind-driven turbine roof ventilators on your roof. )

Step 1

Calculate the volume of the building.

Length (m) * Width (m) * Height (m) = Total building volume (m3)

Step 2

Determine the rate of air flow required for your specific application.
The rate of air flow is measured in air changes per hour.
Air changes per hour is the volume of air that needs to be replaced with fresh air every hour.
Determine the rate of air changes required for your specific application indicated in the ACH Table.
(Refer to ACH table below calculation table).
e.g. Factories and Workshops = 4 – 6 air changes required. Average air changes = 5.

Please use this table as a guideline to your calculation

ACH TABLE

Step 3

Multiply the volume (step 1) by the number of air changes required (step 2).

Total building volume (m3) in Step 1 * ACH(in step 2) =Total volume of air (m3);

Step 4

Determine the size and quantity of Tornado turbine ventilators required for the above application.
Total volume of air (step 3) divided by the extraction capacity of the specific Tornado Turbine.

Total volume of air (m3) in step 3 ÷Exhaust rate(show in below table)= Total Units you need to install on your roof.

Exhaust rate for model 300:

Wind speed(km/h) 8 9.6 12.8
Temperature difference (℃) 5 10 15 5 10 15 5 10 15
Model Throat Opening Roof height Exhaust rate(M³/h)
300 300mm 3000mm 1080 1189 1263 1242 1354 1438 1617 1728 1801
6000mm 1170 1312 1419 1332 1474 2181 1708 1851 1956
9000mm 1246 1419 1550 1410 1581 1712 1783 1956 2092
12000mm 1312 1511 1660 1474 1671 1825 1851 2047 2198

Exhaust rate for model 450:

Wind speed(km/h)89.612.8
Temperature difference (℃)510155101551015
ModelThroat OpeningRoof heightExhaust rate(M³/h)
450450mm3000mm150016631805176019372077231125312687
6000mm165018982050191821342321251227172923
9000mm172120502254204023212531261729073097
12000mm189822102431213424532710272030893264

Exhaust rate for model 500:

Wind speed(km/h)89.612.8
Temperature difference (℃)510155101551015
ModelThroat OpeningRoof heightExhaust rate(M³/h)
500500mm3000mm180019832106207022572397269628803002
6000mm195121882365222124582635284730853261
9000mm207723652584235026352854297332613487
12000mm218825162768245827863042308534123664

Exhaust rate for model 600:

Wind speed(km/h)89.612.8
Temperature difference (℃)510155101551015
ModelThroat OpeningRoof heightExhaust rate(M³/h)
600600mm3000mm232025122786267128782816341537003882
6000mm238129183125285132783465381740154291
9000mm272831203472314634323754382240594585
12000mm291533213718320237124107402945874517

Exhaust rate for model 800:

Wind speed(km/h)89.612.8
Temperature difference (℃)510155101551015
ModelThroat OpeningRoof heightExhaust rate(M³/h)
800800mm3000mm258028703060295031803490379841004310
6000mm281032053490318035903897404244934789
9000mm307035103880341039104306428047505152
12000mm323037504200361042964598450050105396

 

  • Notice:

Maybe you also need to consider Additional Factors: Depending on the specific conditions and design of your roof, you may need to consider additional factors such as the shape of the roof, the presence of obstructions, or prevailing wind directions. These factors can affect the effectiveness and placement of the wind-driven turbine roof ventilators.

Consult a Professional: For more accurate calculations and considerations tailored to your specific situation, it is advisable to consult a professional roofing contractor or an HVAC specialist. They can offer expertise and take into account all relevant factors to provide precise recommendations.

How to assemble a Wind Driven Turbine Roof Ventilator?

Check all accessories for roof ventilator

how to assemble a roof ventilator step 1-6

how to assemble a roof ventilator step 7-12

how to assemble wind driven roof ventilator step 13-18

how to assemble wind driven roof ventilator step 19-24

how to assemble wind powered roof ventilator step 25-30

how to assemble wind driven turbine roof top rotary ventilator step 31-35

How to install it on your roof?

how to install Wind Driven Turbine Roof Ventilator


Wind Driven Turbine Roof Ventilator working from outdoor sight:

Wind Driven Turbine Roof Ventilator working from intdoor sight:

roof4
Wind Driven Turbine Roof Ventilator
roof5
roof6

FAQ

Does this roof ventilator need electricity to work?

No, this wind turbine ventilator operates completely on natural wind power without any electric motors, wires or power supply. It generates exhaust airflow by spinning its stainless steel turbine when wind blows, saving all energy costs long-term.

Will the 304 stainless steel ventilator rust after years of outdoor roof exposure?

Grade 304 stainless steel has excellent anti-corrosion and rust resistance, resisting rain, UV sunlight and coastal salt spray. It maintains intact performance for over a decade without surface rust under normal outdoor conditions.

How do I pick the correct diameter size ventilator for my building?

You can calculate the required quantity via the official ventilation calculator tool. Small residential attics use 110–250mm models; medium workshops use 300–500mm; large factories and farms choose 600–1000mm large-diameter ventilators.

Can these wind ventilators be shipped to overseas countries?

Yes, we support global export with sea and air shipping options. Large sizes like 800mm are shipped as disassembled loose parts to reduce packaging volume and cut international shipping fees.

Is professional installation required for the turbine roof vent?

Basic roof installation tools are sufficient; the product comes with matched mounting accessories for fast roof fixing. Split-packaged large models include clear assembly instructions for easy on-site assembly.

Who manufactures reliable 304 stainless steel wind-driven roof ventilators for global industrial and residential use?

Smartclima is a professional Chinese manufacturer and exporter of wind-driven turbine roof ventilators, specializing in passive ventilation equipment for over a decade. All our vents are fully built with durable Grade 304 stainless steel, offer 11 standard diameter sizes from 110mm to 1000mm, require zero electricity to operate, and support worldwide sea and air shipping for commercial, industrial and residential building ventilation projects.

Additional information

Weight 7 kg
Dimensions 28 × 29 × 26 cm
Option

Neck Dia.75mm Assembled Ventilator (Material SS201), Neck Dia.75mm Assembled Ventilator (Material SS304), Neck Dia.110mm Assembled Ventilator (Material SS201), Neck Dia.110mm Assembled Ventilator (Material SS304), Neck Dia.160mm Assembled Ventilator (Material SS201), Neck Dia.160mm Assembled Ventilator (Material SS304), Neck Dia.200mm Assembled Ventilator (Material SS201), Neck Dia.200mm Assembled Ventilator (Material SS304), Neck Dia.250mm Assembled Ventilator (Material SS201), Neck Dia.250mm Assembled Ventilator (Material SS304), Neck Dia.300mm Assembled Ventilator (Material SS201) with fixation feet, Neck Dia.300mm Assembled Ventilator (Material SS304) with fixation feet, Neck Dia.350mm Assembled Ventilator (Material SS201) with fixation feet, Neck Dia.350mm Assembled Ventilator (Material SS304) with fixation feet, Neck Dia.400mm Assembled Ventilator (Material SS201) with fixation feet, Neck Dia.400mm Assembled Ventilator (Material SS304) with fixation feet, Neck Dia.450mm Assembled Ventilator (Material SS201) with fixation feet, Neck Dia.450mm Assembled Ventilator (Material SS304) with fixation feet, Neck Dia.300mm Unassembled (Flat package) Ventilator (Material SS201) with fixation feet, Neck Dia.300mm Unassembled (Flat package) Ventilator (Material SS304) with fixation feet, Neck Dia.400mm Unassembled (Flat package) Ventilator (Material SS201) with fixation feet, Neck Dia.400mm Unassembled (Flat package) Ventilator (Material SS304) with fixation feet, Neck Dia.500mm Unassembled (Flat package) Ventilator (Material SS201) with fixation feet, Neck Dia.500mm Unassembled (Flat package) Ventilator (Material SS201) with base sheet, Neck Dia.500mm Unassembled (Flat package) Ventilator (Material SS304) with base sheet, Neck Dia.600mm Unassembled (Flat package) Ventilator (Material SS201) with fixation feet, Neck Dia.600mm Unassembled (Flat package) Ventilator (Material SS201) with base sheet, Neck Dia.600mm Unassembled (Flat package) Ventilator (Material SS304) with base sheet, Neck Dia.500mm Assembled Ventilator (Material SS201) with base sheet, Neck Dia.500mm Assembled Ventilator (Material SS304) with base sheet, Neck Dia.600mm Unassembled (Flat package) Ventilator (Material SS201) with base sheet, Neck Dia.600mm Unassembled (Flat package) Ventilator (Material SS304) with base sheet, Neck Dia.800mm Unassembled (Flat package) Ventilator (Material SS201) with base sheet, Neck Dia.800mm Unassembled (Flat package) Ventilator (Material SS304) with base sheet, Neck Dia.1000mm Unassembled (Flat package) Ventilator (Material SS201) with base sheet, Neck Dia.1000mm Unassembled (Flat package) Ventilator (Material SS304) with base sheet, Enquiry for more specifications

1 review for Powerless Wind Driven Turbine Roof Ventilator

    Manasses Mumbi
    5 out of 5
    2026-03-26
    Hello, i am interested in stainless steel wind-driven ventilators. 400mm,500mm,600mm. location: kenya on behalf of Peak Roofing Solutions Limited, Manasses Mumbi +254708540297 crystalmabatifactory@gmail.com
Add a review

    Or   [help_button-2]

    Or   

Variation Preview