Sale!

Universal Air conditioner control system QD-U03C+

Sell Universal Air conditioner control system QD-U03C+.It is always used to control air conditioner system and heat pump system

Features:

  • 5 working mode;
  • High,Medium,Low,three speed control;
  • Accurate and stable temperature control;
  • Accurate and stable auto fan
  • Timer on/off;
  • Sleep;
  • More… …

Place of Origin:

  • Direct-sale by China Manufacturer.
  • Sell to worldwide, Ship by air plane or by sea boat;

Send Enquiry Message

The product was liked and shared by worldwide clients:

Models and Details for “Universal Air conditioner control system QD-U03C+”

Short Description: Universal Air conditioner control system QD-U03C+ is always used to control air conditioner system and heat pump system

5 working mode;
High,Medium,Low,three speed control;
Accurate and stable temperature control;
Accurate and stable auto fan
Timer on/off;
Sleep;
More… …

Feature :

1、5 Working Modes

2、3 Fan Speed

3、Accurate And Stable Temperature Control

4、Accurate And Stable Auto Fan

5、Auto-restart Function

6、Double Sensors

7、Timer on/off

8、Sleep Function

9、Defrost Automatically

10、Outdoor Fan is Controlled Independently

11、Compressor Project Timer For Its Run And Stop

12、Prevent Cold Wind In Heating Mode

13、updated reciever,good looking appearance,show intuitional

14、updated transformer,quick plug, easy for installation

Application :
This product is widely used for air conditioner system and heat pump system,to control the system working automatically.

QD-U03C+-package QD-U03C+-functionQD-U03C+ functionQD-U03C+ componentsQD-U03C+ packingQD-U03C+ wiring

Avoid strong light before IR receiver;
The common pins of swing socket are 12V output;
The common pin of step motor should be inserted into one of the common;
pins of swing socket.lf the direction of step motor is wrong.insert the common pin of step motor to other common pin of swing socket.

QD-U03C+ manual

Manual of “Air conditioner control system QD-U03C+”:
Note:When the compressor is shut off,it needs 3 minutes to restart.
Mode selection key:Select working mode.When in auto mode.the system will work like heat mode if the room temperature
is below 21℃,or work like cool mode if room temperature is up than 27℃.
Fan selection key:Select fan speed.The fan speed will be low when in dry mode,or in heat mode but the compressor is shut
off,or in heat mode but the compressor working time less than 3 minutes. In auto fan mode.the fan speed
will be high if the difference of setting and room temperture big than 4℃,will be low if the difference less
than 2℃.
Temperature setting keys:Be able to set from 16℃-30℃.It will not response in auto mode or dry mode.
Timer selection key:Select timer on.timer off or no timer.
Timer time setting keys:Set 1-16 hours.
Swing key:Select swing on or off.
Sleep key:Will shut off in 8 hours.
Too cool/Too warm keys: Only effective
in auto mode-Be able to adjust the setting temperature 1℃ up/down from 25℃ when depressing once the key
ON/OFF key:Control on or off.

New package:

 

universal air conditioner control system qd u03c+

Universal Air conditioner control system QD-U03C+ 1

universal air conditioner control system qd u03c 1

 How to purchase “Universal Air conditioner control system QD-U03C+”

  • The PCB kit  is available for retail and wholesale;
  • The place of origin is in China,when you buy one or two,please consider freight(by air or by sea) into the cost;
  • Accept bulk order with Container delivery;
  • Please contact us online (click here) Or send inquiry message to our email:  airconditioner@smartclima.com

Enquiry or Reviews

5 Star

12.5 %
1 review(s)

4 Star

0 %
0 review(s)

3 Star

0 %
0 review(s)

2 Star

0 %
0 review(s)

1 Star

0 %
0 review(s)

0 Star

87.5 %
7 review(s)

Reviewed by 08 customer(s)

  • Amir Rasheed

    Please share price and availability of following item.
    (1).UNIVERSAL AIR CONDITIONER CONTROL SYSTEM MODEL:QD-U03C+
    Qty .05

    2022-11-14
  • Ignas Haule

    Universal A/C control system QD-U03C+ quotation.

    2022-01-05
  • Jaco

    Where is the 12vdc negative pin for blower fan?

    2020-02-25
  • sassy

    I have Panasonic A/C and board inside the panel broken therefore I got this board to start and getting cool but it is not functioning with Panasonic and I couldn’t get cool or even middle, it is like the hell, what to do with this problem…? appreciate

    2019-07-07
  • Bozhidar

    I have an 2006 model vaillant va 6-050 inverter air conditioner with a broken pcb, will this work on it??

    2019-02-06
  • Barry du Plessis

    Please help with connections on INDOOR Fan motor
    fan motor has 6 wires a Black Neureal b White Live to running winding c Red to running winding via cap
    Other 3 Brown, grey ,yellow ( Differant speed)
    Making use off QD -IO3C Universal Conbtrol System

    2017-01-30
  • Henry

    Struggling with connection of indoor fan, fan motor on unit has six wires, have determined which one is Live, neutral, earth and the three speeds. How do I connect it. Please assist if you can?

    2016-11-03
  • TAIB M.R.

    HI
    I USE AIR CONDITIONER CONTROL SYSTEM (QD_U03C+) MOSTLY IN MY POWER PLANT & TO BECOME MORE FAMELY WITH THIS CONTROL SYSTEM I NEED DETAILES INFORMATION AND FUNCTION OF THREE ICS USED IN PCB
    PLEASE CAN YOU HELP ME?
    THANK YOU WITH BEST RESPECT

    2014-11-23
    • Smartclima

      2015-04-25

      Hi
      PLEASE CAN YOU send the circuit diagram of QD-u03C A/C controller
      THANK YOU WITH BEST regard
      SAEED hilaly

Write enquiry message or review

Rate Your Satisfaction*