Thermodynamic Solar Block(heat block) is mainly part in thermodynamic panel system.It is controlled by computer panel to drive refrigerant from panel to compress,then the heated refrigerant is driven into the solar copper coil inside of water cylinder.The block couldn`t work indepently.It must work with thermodynamic panel together.
Thermodynamic Solar Block
Thermodynamic Solar Block made by Smartclima has two types as following:
Model
TSP02
TSP03
Power
~220V 50HZ
~220V 50HZ
Rated Water Output Temperature
55℃
55℃
Rated Heat Capacity Output (W)
1670W
3880W
Rated Power Input(W)
370W
800W
Rated Current Input(A)
1.7
3.7
Noise ( (dB) A)
≤ 45
≤45
Panel Size(mm) & Panel Qty.
1700×800, 1 panel
1700×800, 2 panels
Water Tank Capacity(L)
100L,150L,200L
300L,500L
Sub-Models
TSP02-100, for 2-3 persons
TSP02-150, for 3-4 persons
TSP02-200; for 4-6 persons
TSP03-300, for 7-8 persons
TSP03-500, for 8-10 persons
Applicable Environment Temp.
-15℃/45℃
-15℃/45℃
Thermodynamic Solar Block Running operation(Touch Panel)
1.Switch the unit : Press “Power” button to decide “On / Off” mode, the heating indicator will be on, the tank temperature is showed at the left and the current tank temperature is showed at the middle and also,time,week and day or night are showed at the above.
2.Set time: Press ” SET” for 5 seconds and you can choose ” calibration of hour “, “calibration of minute ” ,” calibration of week “, ” hour set for time to start ” ,”minute set for time to start ” ,” hour set for time to shut down “,”minute set for time to shut down “.
Press ” UP ” “DOWN” to calibrate or to set time to start/shut down.
Press ” SET” for 5 seconds in time calibration mode and then press “SET” again in time setting mode.
Press “ON/OFF” once to open the function of time to start and press “UP” “DOWN” to adjust time; To cancel the this function: press ” SET” for 5 seconds and then press ” SET” again to time to start, press “ON/OFF” once and the function can be canceled.
To set the time / to shut down is the same with time to start.
3.Set temperature:
Press “SET” to set temperature mode and press “UP” “DOWN” to set water tank temperature. Press ” SET” once to cancel the temperature set.
4.Instruction for key operation:
ON/OFF key : to start or shut down the unit ; time to start or time to shut down the unit.
SET key : to set water tank temperature ; press this key for 5 seconds to set time, week and timing.
UP/DOWN :In operation, press “UP” “DOWN” to adjust the setted temperature.In calibration of time / timing ,press “UP” “DOWN” to adjust the setted time.