Thermodynamic expansion valve TCLE/TRFE Series
$1.00 ( Not real price )

Thermodynamic expansion valve TCLE/TRFE Series
TCLE / TRFE series thermal expansion valve is a split expansion valve, suitable for a wide range of fields such as air conditioning, commercial refrigeration, transportation air conditioning and refrigeration.
Features
The spliced structure is simple and easy to repair, and the power head and valve core can be replaced by removing the fixing bolt.
Stable superheat is manifested.
Can provide MOP (motor overload protection) function.
Available in various takeover sizes and forms.
Suitable for R22, R134a, R407C, R404A / R507 refrigerants and other media.
Please contact Shangheng for special requirements
Place of origin: Made in China, export to worldwide.
Order or Inquiry on “Thermodynamic expansion valve TCLE/TRFE Series ” |
Models & Details for “Thermodynamic expansion valve TCLE/TRFE Series ” |
Selection form Technical data
|
R134a |
R22 | R407C | R404A / R507 | R410A | ||||||||||
| model | Nominal capacity | model | Nominal capacity | model | Nominal capacity |
model |
Nominal capacity |
model |
Nominal capacity | |||||
| (KW) | (KW) | (KW) | (KW) | (KW) | ||||||||||
| TCLE | 1 / 4M | 1.2 | TCLE | 1 / 2H | 1.76 | TCLE | 1 / 2N | 1.68 | TCLE | 1 / 3S | 1.17 | TCLE | 2/3Z | 2.20 |
| TCLE | 3 / 4M | 2.29 | TCLE | 1H | 3.52 | TCLE | 1N | 3.49 | TCLE | 2 / 3S | 2.35 | TCLE | 1-1/4Z | 4.40 |
| TCLE | 1-1 / 2M | 4.93 | TCLE | 2H | 7.04 | TCLE | 2N | 7 | TCLE | 1-1 / 2S | 5.28 | TCLE | 2-1/2Z | 8.80 |
| TCLE | 2-1 / 2M | 10.91 | TCLE | 3H | 10.55 | TCLE | 3N | 10.23 | TCLE | 2S | 7.04 | TCLE | 3-1/2Z | 12.30 |
| TCLE | 3-1 / 2M | 14.08 | TCLE | 5H | 17.6 | TCLE | 5N | 16.8 | TCLE | 3-1 / 2S | 12.32 | TCLE | 6Z | 21.10 |
| TCLE | 5-1 / 2M | 19.36 | TCLE | 7-1 / 2H | 26.4 | TCLE | 7-1 / 2N | 25.75 | TCLE | 5S | 17.6 | TCLE | 9Z | 31.36 |
| TCLE | 7-1 / 2M | 26.05 | TCLE | 10H | 35.2 | TCLE | 10N | 34.78 | TCLE | 7S | 24.64 | TCLE | 12Z | 42.20 |
| TCLE | 9M | 30.72 | TCLE | 12H | 42.24 | TCLE | 12N | 41.85 | TCLE | 8-1 / 2S | 29.92 | TCLE | 15Z | 52.80 |
| TRFE | 11M | 38.72 | TRFE | 14H | 49.28 | TRFE | 14N | 47.93 | TRFE | 10S | 35.2 | TRFE | 17Z | 6.00 |
| TRFE | 13M | 45.76 | TRFE | 18H | 63.36 | TRFE | 18N | 61.59 | TRFE | 12S | 42.24 | TRFE | 22Z | 77.40 |
| TRFE | 16M | 56.32 | TRFE | 22H | 77.44 | TRFE | 22N | 75.88 | TRFE | 15S | 52.8 | TRFE | 26Z | 91.50 |
| TRFE | 19M | 66.36 | TRFE | 26H | 91.52 | TRFE | 26N | 90.79 | TRFE | 18S | 63.36 | TRFE | 30Z | 105.00 |
| TRFE | 25M | 84.48 | TRFE | 35H | 123.2 | TRFE | 35N | 121.9 | TRFE | 25S | 88 | TRFE | 42Z | 147.80 |
| TRFE | 31M | 105.6 | TRFE | 45H | 158.4 | TRFE | 45N | 156.78 | TRFE | 32S | 112.64 | TRFE | 55Z | 193.60 |
| TRFE | 45M | 147.84 | TRFE | 55H | 193.6 | TRFE | 55N | 191.41 | TRFE | 38S | 133.76 | TRFE | 65Z | 228.80 |
| TRFE | 55M | 193.6 | TRFE | 75H | 264 | TRFE | 75N | 262.5 | TRFE | 52S | 183.04 | TRFE | 90Z | 316.80 |
| TRFE | 68M | 228.8 | TRFE | 100H | 352 | TRFE | 100N | 350.17 | TRFE | 70S | 246.4 | TRFE | 100Z | 352.00 |
| TRFE | 80M | 280.6 | TRFE | 120H | 420.7 | TRFE | 120N | 416.7 | TRFE | 84S | 295.7 | TRFE | 140Z | 492.00 |
Note: The nominal cooling capacity is based on the evaporation temperature t e = 4.4 ° C, the condensation temperature t c = 40 ° C, and the temperature of the refrigerant in front of the valve is t 1 = 37.8 ° C.
Note: Nominal capacity is based on evaporating temperature t e = 4.4 ℃, condensing temperature t c = 40 ℃, and refrigerant temperature ahead of valve t 1 = 37.8 ℃.
Note: For other working characteristics and specifications, please contact our company.
Note: If you have special requirement, please contact us
Superheat adjustment
The factory superheat degree is set to 3.4K, and the static superheat degree adjustment range is 2 to 8K.
Turn the lever counterclockwise one turn to reduce the superheat by 0.3K.
Dimensions
|
model
|
Takeover form
Form of connection
|
Standard takeover
Connecting size
|
A
mm
|
B
mm
|
C
mm
|
D
mm
|
E
mm
|
F
mm
|
G
mm
|
H
mm
|
I
mm
|
Capillary length
Capillary length
|
|
|
import
Inlet
|
Export
Outlet
|
||||||||||||
|
TCLE
|
Straight-through
Straight-thru
|
∅16 ODF
Or 5/8
|
∅16 ODF
Or 5/8
|
94
|
65
|
65
|
30.5
|
17
|
122
|
∅13
|
62
|
44.5
|
1.5m
|
|
Right angle
Angle
|
∅16 ODF
Or 5/8
|
∅16 ODF
Or 5/8
|
138
|
65
|
65
|
30.5
|
61
|
122
|
∅13
|
62
|
44.5
|
||
|
TRFE
|
Straight-through
Straight-thru
|
∅22 ODF
Or 7/8
|
∅22 ODF
Or 7/8
|
138
|
55
|
49
|
44
|
90
|
122
|
∅13
|
65
|
44.5
|
1.5m
or
3m
|
|
∅28.5 ODM
Or 1-1 / 8
|
∅28.5 ODM
Or 1-1 / 8
|
||||||||||||
|
Right angle
Angle
|
∅22 ODF
Or 7/8
|
∅22 ODF
Or 7/8
|
138
|
55
|
49
|
44
|
90
|
122
|
∅13
|
65
|
44.5
|
||
|
∅28.5 ODM
Or 1-1 / 8
|
∅28.5 ODM
Or 1-1 / 8
|
||||||||||||
|
Flanged
Flange
|
∅33X3.5
|
∅33X3.5
|
123
|
115
|
85
|
111
|
∅35
|
122
|
∅13
|
–
|
–
|
||
Note: If there are special requirements for capillary length, please contact us.
Note: If you have special requirement, please contact us.
Models and Drawings:

How to purchase “Thermodynamic expansion valve TCLE/TRFE Series ” |
- The item is available for retail and wholesale;
- The place of origin is in China,when you buy one or two,please consider freight(by air or by sea) into the cost;
- Accept bulk order with Container delivery;
- Please contact us to email: hvac@smartclima.com
Additional information
| Weight | 3 kg |
|---|---|
| Dimensions | 21 × 17 × 16 cm |
Be the first to review “Thermodynamic expansion valve TCLE/TRFE Series” Cancel reply





Reviews
There are no reviews yet.