logo

Sea water coaxial heat exchanger

HVAC Parts >>Refrigerating Parts & Heating Elements>>Heat Exchangers>>Sea water coaxial heat exchanger

Sea water coaxial heat exchanger

Item: Sea water coaxial heat exchanger

Short Description: A device especially used for sea water heating exchange.Inner tube is made from Cu/Ni,which has very good performance of corrosion resistance;Outer tube is made from hot dipped galvanized tube;Sea water flows in the inner tube and refrigerant flows between inner tube and outer tube,during flowing,exchanging heat.The whole item is insulatd.The best feature of this heat exchanger is corrosion resistance and high energy exchanging effience.They are always used in the ship,boat, and other marine device.

Place of origin: China, Sell to worldwide

Order or Inquiry on “Sea water coaxial heat exchanger
Models & Details for “Sea water coaxial heat exchanger”

Type A- Single refrigerant tube

               Item
Model
Cooling
Capacity(KW)
Heating
Capacity(KW)
Water Flow
(m³/h)
Water Resistance(Kpa) For Compressor
(Hp)
SCE05 5.3 6.2 0.89 <40 2
SCE06 6.1 7 1 <40 2.5
SCE08 7.8 9.1 1.3 <40 3
SCE10 10.2 11.5 1.7 <40 4
SCE13 12.7 14.4 2.1 <40 5
SCE15 15.1 16.9 2.6 <40 6
SCE18 17.8 19.7 3 <40 7.5
SCE20 20.2 22.5 3.5 <40 8
SCE23 22.8 24.7 3.9 <40 9
SCE25 25.7 28.1 4.3 <40 10
SCE28 27.7 31.2 4.7 <40 11
SCE30 30.1 33.7 5.2 <40 12
SCE35 34.5 38.2 5.9 <40 14
SCE40 41 45.7 6.9 <40 16
SCE45 45.8 51.3 7.7 <40 18
SCE50 50.6 56.7 8.6 <40 20
SCE55 55.7 62.3 9.4 <40 22
SCE60 60.4 67.5 10.3 <40 25
SCE63 62.7 70.2 10.8 <40 25
SCE75 77.2 86.3 12.9 <40 30
SCE90 91.6 102.7 15.4 <40 35
SCE100 101.3 113.5 17.1 <40 40
SCE110 110.8 124.4 18.9 <40 45
SCE125 125.4 140.8 21.4 <40 50

Sea water coaxial heat exchanger parameter

                        ModelItem SEC05
SEC06
SEC08
SEC10
SEC13
SEC15
SEC18
SEC20
SEC23
SEC25
SEC26
SEC30
SEC35
SEC40
SEC50
SEC60
SEC45
SEC55
SEC63
Refrigerant Inlet C3(mm) 12 12 16 19 25
L1(mm) 496 589 736 1007 991
W4(mm) 178 218 244 305 413
H3(mm) 205 205 209 225 245
Refrigerant Outlet C2(mm) 16 19 22 25 40
L6(mm) 485 574 721 987 996
H5(mm) 230 235 215 195 305
W5(mm) 82 96 114 125 153
Water Inlet C1(mm) 3/4″ 1″ 1″ 11/2″ 2″
W6(mm) 214 282 320 400 500
H1(mm) 277 293 283 275 405
L2(mm) 429 512 654 905 876
Water Outlet C1(mm) 3/4″ 1″ 1″ 11/2″ 2″
W3(mm) 245.5 318 364 455 563
H4(mm) 112 125 139 155 183
L2(mm) 429 512 654 905 876
Air relief valve L5(mm) 37 42 42 53 53
Fixed Size C4(mm) 7X12 7X12 9X15 9X15 13X20
L4(mm) 136 175 199 250 310
L3(mm) 261 300 419 610 535
W2(mm) 277 354 408 510 626

Note:

  •  C1 is external thread, can be welded with flange;
  •  C2, C3 is flared inside diameter;
  • The sizes are the dimension without insulation coated;
  • Can be customized size;

 

Type B- Double refrigerant tube

Sea water coaxial heat exchanger specification

SEC06D SEC10D
SEC15D
SEC20D SEC25D
SEC30D
SEC40D  SEC45D
SEC50D  SEC55D
SEC60D  SEC63D
A 40 40 40 40 60
B 42 42 52 64 74
C Φ9.52 Φ12 Φ12 Φ16 Φ19
D Φ12 Φ16 Φ16 Φ19 Φ25

* Other dimensions,please refer to above Type A- Single refrigerant tube

 

Buying Guide to “Sea water coaxial heat exchanger”
  • The heat exchanger is available for retail and wholesale;
  • The place of origin is in China,when you buy one or a small quantity,please consider international sea or air freight as cost;
  • Accept bulk order with Container delivery;
  • Accept customized production;
  • More types of coaxial heat exchanger are not displayed on the web.If the item above doesn`t meet your requirement,please contact us to email: [email protected] ,we can supply a favourite item you need.
General Knowledge on “Sea water coaxial heat exchanger”

coaxial-heat-exchanger-work

Theory of Coaxial heat exchanger:

Coaxial heat exchanger has tube-in-tube and twisted inner tube designs. Rugged tube surface can maximize the overall heat trans

The resulting convoluted tube has increased heat transfer surface area per unit length yet still permits full flow of both water and refrigerant around its entire periphery for improved performance. Turbulence imparted by the convolutions to both the water and refrigerant flows further enhances the thermal performance, while inhibiting the accumulation of deposits on the surfaces. The net result is a highly effective, compact heat exchanger with superior anti-fouling characteristics.

Feature of Coaxial heat exchanger:

1, High efficiency heat transfer: Because of using titanium corrugated tube, the flow channel continuously mutation, so that it always in a highly turbulent although the fluid velocity is very low. It is very difficult to become a laminar flow, and the main resistance for convective heat had being overcome. Simultaneously, the heat transfer are enhanced. so it has high efficiency heat transfer, more than the titanium plain tubes in 2 to 3 times.

2, Anti-fouling ability: The particles in the fluid are difficult to forming in the high turbulence in the flow channel. However, even with a small amount of scale formation on the wall, the turbulence of medium in the pipe, which is strongly erosion anti-fouling ability. Furthermore, it changes the stress of the different temperature between the inner tube and the outer tube, and the curvature of the thread pipe which has elastic characteristics has been changed lightly. That is why the threaded tube heat exchanger has the ability of antifouling and descaling.

3, Strong stress compensation ability: Because of the characteristics of thin-walled, elastic and structural shape threaded pipe, the curvature was changed lightly when the large temperature difference the inner tube and the outer tube to compensate and eliminate the thermal stress. Consequently to prevent the traditional tube heat exchanger to cracking efficiently.

4, With compact structure, small and light: The heat transfer coefficient of the threaded pipe heat exchanger is very high, and the required heat transfer areas are little, also with the small wall thickness, so the titanium corrugated tube heat exchanger has compact structure, small size and light weight.

One Inquiry to Sea water coaxial heat exchanger