Item: Microcomputer dual output automatic temperature control instrument XH-W2024
Temperature control type: constant temperature dual output Temperature range: -50 – + 110℃ Temperature control accuracy: 0.1℃ Resolution: 0.1℃ Refresh frequency: 0.5S Temperature control probe: waterproof type thermistor 1 meter long line; Product size: 77x35x88mm Opening size: 70x29mm Output Type: Relay Output Maximum Capacity 1OA Power supply: 12V / 24V / 220V optional
Place of origin: China factory sell directly , Sell to worldwide.
Models & Details for “Microcomputer dual output automatic temperature control instrument XH-W2024”
Technical Parameters: Product Name: Microcomputer dual output automatic temperature control instrument Product Type: XH-W2024 Temperature control type: constant temperature dual output Temperature range: -50 – + 110℃ Temperature control accuracy: 0.1℃ Resolution: 0.1℃ Refresh frequency: 0.5S Temperature control probe: waterproof type thermistor 1 meter long line; Product size: 77x35x88mm Opening size: 70x29mm Output Type: Relay Output Maximum Capacity 1OA Power supply: 12V / 24V / 220V optional
Set temperature Press once to display the temperature value, press SET to modify, also can modify by P1 Press once to display the soil temperature difference, press SET to modify, also can be modified by P2 P1: constant temperature value The number of degrees that the user needs to set ; P2: temperature difference When the real-time temperature> constant temperature value + temperature difference, start the cooling, work up to the constant temperature to stop; When the real-time temperature <temperature difference – temperature difference, start heating, work up to the constant temperature to stop; P3: Heating delay When you need to start heating, it will not start heating immediately, you need to run the P3 value ,and then will start. when delay,the corresponding heating lamp will flash. Set the unit in seconds, if you do not need to delay, and need to start immediately, you can set the value 0; P4: Cooling delay When the need to start the cooling,it will not immediately start the cooling, you need to run the P4 value ,and then will start. when delay ,the corresponding cooling light will flash. Set the unit in seconds, if you do not need to delay, and need to start immediately, you can set the value 0; P5: high temperature alarm You can set a group above the upper limit of the temperature value for the high temperature alarm, when the temperature is higher than this value, the screen temperature flashing,the buzzer beeps when the temperature is below the alarm. P6: low temperature alarm Can set a group below the lower limit of the temperature value for the low temperature alarm, when the temperature below this value, the screen temperature flashing,the buzzer beeps when the temperature is higher than the value,the alarm automatically released; P7: Temperature correction When the temperature value and the actual temperature value display error, can be corrected by this function, the corrected value will automatically be added to the real-time temperature, such as: display temperature = temperature measurement temperature + temperature correction.
The main screen displays the real-time temperature, and the set value is displayed when the setting is made Set: Set button, press this button to enter the internal parameter setting; Rst: Confirm button, press this key to confirm after setting, press and hold to switch on; For the display settings and temperature difference value, when make set function,it is changed to” increase the key and reduce the key”; The heating / cooling indicator lights up, indicating that the corresponding output is closed and the flashing indication is in a delay.
Main function ‘ This controller can set to a temperature and a temperature difference, for example, set the temperature of 25℃, the temperature difference of 1, when temperature is lower than 25-1 start heating, heating up to 25℃ to stop; when the temperature is higher than 25 + 1 start cooling, cooling to 25℃ to stop, So,to achieve automatic temperature keeping!
Basic settings: Press once to display the set temperature, press SET to modify, or long-time press the SET to display P1 for modification; Press once to display the temperature difference, press SET to modify, or long-time press the SET to display P2 for modification;
Error code: LLL: The sensor is disconnected or damaged; HHH: The sensor is snapped or out of the measuring range Screen flash: in the set state or prompt for high and low temperature alarm Indicator flashes: in the delay state, need to wait for the end of the delay to start;
Internal settings: Long-time press Set 5 seconds to enter the internal menu settings .
Menu function description Press SET and hold Set 5 seconds to display P1, press to switch P1-P7, then press Set once to enter the setting parameter,after 10 seconds to complete the automatic confirmation to return, you can also press Rst immediately confirm the return.
Buying Guide to “Microcomputer dual output automatic temperature control instrument XH-W2024”
The Digital temperature controller is available for retail and wholesale;
The place of origin is in China,when you buy one or a small quantity,please consider freight into the cost;
Accept bulk order with Container delivery;
Please contact us to email: econtrol@smartclima.com ,we can supply a favourite item you need.
Be the first to review “Microcomputer dual output automatic temperature control instrument XH-W2024”