Item: Microcomputer digital thermostat temperature controller XH-W1321
Temperature control type: constant temperature dual output Temperature range: -50 – + 110℃ Temperature control: -50 – + 110℃ Temperature control accuracy: 0.1℃ Resolution: 0.1℃ Temperature control probe: NTC10K,Waterproof type thermistor 1 meter long; Product size: 56x38x32mm Opening size: 46x34mm Output Type: Relay Output Maximum Capacity 10A Power supply: 12V/ 220V optional
Place of origin: China factory sell directly , Sell to worldwide.
Models & Details for “Microcomputer digital thermostat temperature controller XH-W1321”
In normal using,press once, directly enter into the stop temperature setting state, use the up and down keys to set the required stop temperature, long-time press to enter the internal settings menu; Long-time press the SET button to enter the internal settings, use the up button to increase the value set; Long-time press the SET button to enter the internal settings, use the down button to reduce the value setting;
Set hysteresis Why do you want to set the hysteresis setting? When the control device, the temperature will rise or fall, how many degrees of temperature change equipment to work again? If you want the temperature changes 10 ℃, the device work again, you need to set the back value of 10, by setting Hysteresis, the device can be in the temperature range of reciprocating work.
Set the stop temperature Normal display state press the set button once to stop the temperature Digital flash, you can set the required stop temperature value by using the up and down keys; How do I restore factory settings? Power on the situation, while holding down the up and down keys, digital display 888, then automatically jump to the detection temperature, that is, to restore the factory settings;
P0: working mode This value must be set for the first time to use the thermostat. If it is used for heating, it should be set to H; if it is used for cooling, it is necessary to set to C. P1: hysteresis setting Long-time press the set button for 3 seconds ,enter into the internal menu, select P1, then press the set button, enter the hysteresis value set state. Hysteresis is the value that,when the thermostat reaches the set temperature, then stop working, the need to work again the difference, such as set to the heating mode, heating to 40 ℃ stop, down to 35 ℃ again, the hysteresis is 5;
P2: temperature correction Press and hold the key for 3 seconds to enter the internal menu, press the up and down keys to select P2, then press the set button, through the up and down keys to set the required calibration temperature. In the setting, if the detected temperature value is 0.5℃ higher than the actual temperature value, the calibration temperature to be set is -0.5℃. If the detection temperature is 1℃ lower than the actual temperature, the calibration temperature to be set is 1℃. Detection temperature +/- correction temperature = actual temperature.
P3: delay start Press and hold the key to set the desired delay time (minutes). Press the up and down keys to set the desired delay time (minutes). Delay start is generally used for compressor cooling, if used for refrigerator freezer, this value needs to be set, according to the compressor back pressure size is generally set to 3-6 minutes, if you are not used to control the compressor or do not need to delay Function, skip this item directly.
Error code: LLL: The sensor is disconnected or damaged; HHH: The sensor is snapped or out of the measuring range Screen flash: in the set state or prompt for high and low temperature alarm Indicator flashes: in the delay state, need to wait for the end of the delay to start;
Heating settings: Set the essentials: The first step set PO = H, the second step to set the stop temperature, the third step set the hysteresis value; Set the way: 1. Press and hold the key to enter the internal menu and set PO to H 2. Press the Setup button to stop the temperature flashing, the up and down keys to set the temperature; 3. Press and hold the key to enter the internal menu, set the P1 hysteresis setting; Use case: Control the water heater. Heating to 65 ℃ stop, the temperature dropped to 50 ℃ again start heating, how to set up? Step 1: Determine the operating mode as heating mode, set P0 to H; Step 2: Press the set button to stop the temperature flashing, through the up and down keys to set the starting temperature of 50 ℃; Step 3: stop at 65℃, start again at 50℃, so the hysteresis needs to be set to 65-50 = 15, enter the internal menu to set P1 to 15, complete;
Cooling mode setting method. Set the first step to set P0 = C, the second step to set the stop temperature, the third step to set the hysteresis value; Set the way: 1. Press and hold the key to enter the internal menu, set the PO to C; 2. Press the Setup button to stop the temperature flashing, the up and down keys to set the temperature; 3. Press and hold the key to enter the internal menu, set the P1 hysteresis setting;
Use case: Control the farm, ventilation to 26 ℃ to stop, the temperature rose to 28 ℃ to start the cooling again, how to set up? Step 1: Determine the operating mode for the cooling mode, set P0 to C; The second step: press the set button to stop the temperature flashing, through the up and down keys to set the stop temperature of 28 ℃; The third step: 26 ℃ stop, 28 ℃ start again, so the hysteresis need to be set to 28-26 = 2, enter the internal menu will be set to 2, 2, finish cooling case set.
Prompt: Set the time, if you accidentally set the working mode and set their own stop temperature is not the corresponding, the indicator light will not light, the load does not work
, If the above situation, you can view the P0, P1, P3.
Buying Guide to “Microcomputer digital thermostat temperature controller XH-W1321”
The Digital temperature controller is available for retail and wholesale;
The place of origin is in China,when you buy one or a small quantity,please consider freight into the cost;
Accept bulk order with Container delivery;
Please contact us to email: econtrol@smartclima.com ,we can supply a favourite item you need.
1) using the 12 Volt mode 2) Using K1 & K2 to replace analog thermostat. 3) When k1 & k2 is closed output light is on & an alarm is energized. 4) Our problem is that we do not want the alarm to sound when the contacts k1 & k2 are made.