Intelligent dehumidification device for power distribution cabinet intelligent Drainage type dehumidifier model CS001 SYZ-C2000B
$28.00 ( Not real price )
Sell Intelligent dehumidification device for power distribution cabinet intelligent Drainage type dehumidifier model CS001/SYZ-C2000B.
- Working power supply: AC/DC85-265V, power 20W.
- Direct-sale by China Manufacturer.
- Sell to worldwide, Ship by air plane or by sea boat;
Models and Details for “Intelligent dehumidification device for power distribution cabinet” |
1,Overview-
The intelligent dehumidification device adopts semiconductor refrigeration and dehumidification method to actively move the confined space
The humid air is sucked into the dehumidification duct under the action of a fan, and the water vapor in the air condenses into water after passing through the semiconductor refrigeration mechanism, and then discharges into the cabinet through the water pipe, which can achieve a good dehumidification effect.
2. Technical parameters –
2.1 Input specifications: 1 humidity input module
2.2 Measurement range: Humidity: 0%RH~99%RH
2.3 Basic error
Humidity: ±3%RH (10%RH~90%RH), ±5%RH (0%RH~99%RH)
2.4 Resolution: humidity 0.1%RH
2.5 Working power supply: AC/DC85-265V, power 20W.
2.6 Working environment: non-corrosive occasions with a temperature of 0°C~50°C and a humidity of <85%RH.
Dimensions:87*71*51mm (Height*width*thickness)



How to Set? |



Communication by RS485 |
Protocol:
We specify the communication data format used in this dehumidifier: bits per byte (1 start bit, 8 data bits, no checksum, 1 stop bit).
The structure of the data frame, that is, the message format:

Device address: It consists of one byte. In our system, only 1~99 are used, and other addresses are reserved. The address of each terminal device must be unique, and only the addressed terminal will respond to the corresponding query.
Function code: tells the addressed terminal what function to perform. The following table lists the function codes supported by this dehumidifier and their functions.

Data segment: Contains the data required by the terminal to perform specific functions or the data collected when the terminal responds to queries. The content of these data may be numerical values, reference addresses or setting values.
Check code: CRC16 occupies two bytes and contains a 16-bit binary value. The CRC value is calculated by the transmitting device and then appended to the data frame. The receiving device recalculates the CRC value when receiving the data and then compares it with the value in the received CRC field. If the two values are not equal,then it occurs mistake.
Examples of communication messages:
Host read communication address (register address 7):

Communication address description:

How to purchase “Intelligent dehumidification device for power distribution cabinet” |
- The device is available for retail and wholesale;
- The place of origin is in China,when you buy one or two,please consider freight(by air or by sea) into the cost;
- Accept bulk order with Container delivery;
- Please contact us online (click here) Or send inquiry message to our email: sale@smartclima.com
![]()
Additional information
| Weight | 10 kg |
|---|---|
| Dimensions | 11 × 6 × 17 cm |
Related products
-

High-precision temperature and humidity controller model XH-M453 digital display dual output synchronization range -20℃ to 60℃ 0-100%RH DC12V~24V AC220v
-

Intelligent Digital Display Temperature and Humidity Controller model XK-W1099
-

Dial type temperature and humidity controller for dehumidification of power distribution cabinet temperature -20°C to 70°C, humidity<95%RH AC220V
-

Distribution box electrical cabinet anti-condensation dehumidification controller model SYZ-CS8000B
-

Intelligent digital temperature and humidity display controller switch range -19.9℃ to 99.9℃ 0-99.9%RH AC/DC90~260V




Reviews
There are no reviews yet.