Heating elements electric heater
Flange heating
Flange heating uses and considerations:
1. Flange below must be completely immersed in water, which avoid burn out components, the water is heated should be non-corrosive, the corrosive liquids to be customized.
2. When the pipe surface scale, must be divisible to use, so as not to reduce the efficiency and even cause instant dry, burned out heating tube.
3. The product should be stored in a dry place ,if long-term placement of the insulation resistance dropped to less than one megohm, also can be dried in the oven 200 degrees for several hours(Or components of low-voltage electricity, more than one series of a few hours)so that can restore the insulation resistance.
4.The following table are conventional form,the default of flange material is 302,if has non-standard products to be customized .
Specifications(L+H) | caliber | voltage | power |
HSU-200+50 | Φ12 | 220V | 1KW |
380V | |||
HSU-250+50 | 220V | 1.5KW | |
380V | |||
HSU-300+50 | 220V | 2KW | |
380V | |||
HSU-350+50 | 220V | 2.5KW | |
380V | |||
HSU-400+50 | 220V | 3KW | |
380V | |||
HSU-450+50 | 220V | 3.5KW | |
380V | |||
HSU-500+50 | 220V | 4KW | |
380V |
specifications(L+L2+H) | caliber | voltage | power |
HSS2-300+200+50 | Φ12 | 220V | 3KW |
380V | |||
HSS2-350+230+50 | 220V | 3KW | |
380V | |||
HSS2-400+280+50 | 220V | 4KW | |
380V | |||
HSS2-450+320+50 | 220V | 5KW | |
380V |
The diameter of the corresponding flange parameters
Note: the form of the conventional electric heat pipe
The pairing of flange material are iron nickel plating.
Pipe diameter | Flange size |
Φ8 | M12X18 |
Φ10 | M16X28 |
Φ12 | M18X28 |
Φ16 | M22X33/M22X45 |
Φ20 | M27X45 |
HSQ6 heater
HSQ6 heater internal uniform distribution of high-temperature resistance line, fill in the thermal conductivity and good insulating properties of crystalline Mgo powder in the gap part of the dense.
The heater of this structure is not only high thermal efficiency and heat evenly. When the current through the high temperature resistance wire, heating tube heat generated by surface diffusion through the crystalline Mgo powder to the metal tube to be heated or air pass to reach the purpose of heating.
specifications | voltage | power | material | specifications | voltage | power | material |
16X300 | 110V | 300W | iron、stainless steel | 16X900 | 220V | 900W | iron、stainless steel |
16X350 | 110V | 350W | 16X1000 | 220V | 1000W | ||
16X400 | 110V | 400W | 16X1100 | 220V | 1100W | ||
220V | 16X1200 | 220V | 1200W | ||||
16X450 | 110V | 450W | 16X1300 | 220V | 1300W | ||
220V | 16X1400 | 220V | 1400W | ||||
16X500 | 110V | 500W | 16X1500 | 220V | 1500W | ||
220V | 16X1600 | 220V | 1600W | ||||
16X550 | 220V | 550W | 16X1700 | 220V | 1700W | ||
16X600 | 220V | 600W | 16X1800 | 220V | 1800W | ||
16X700 | 220V | 700W | 16X1900 | 220V | 1900W | ||
16X800 | 220V | 800W | 16X2000 | 220V | 2000W |
Note: forms are for regular size, the caliber Φ6 ~ Φ20 the non-standard pipe diameter need to customize, more pictures can reference product selection chart.
SY series heater
HSY series heater, is widely used in the petrochemical, metallurgy and other industries in China.
HSY2 products, per unit area of the heating power are relatively high, the following table is generic products, you can use special occasion.
HSY4 product is heated in a closed tank, the HSY2 ordinary tubular electric heater based on the improvement of wiring devices and heating structure, three heating tube as a group, effectively reduces the surface of the heater load can be directly to substitute SHY2 heater.
The HSY series will be bending the original tubular welded to the flange on the composition, the heater is placed directly on the heating oil, high thermal efficiency and long service life. 1KW to 4KW, the work environment is about 300 ℃, and 5KW to 8KW suitable to work in about 100 ℃ environment.
Model | Length | Voltage | Power |
HSY2-1 | 230 | 220V 380V | 1KW |
HSY2-2 | 430 | 2KW | |
HSY2-3 | 630 | 3KW | |
HSY2-4 | 845 | 4KW | |
HSY4-5 | 520 | 5KW | |
HSY4-6 | 720 | 6KW | |
HSY4-8 | 920 | 8KW |
Remark: 1.115 flange is the universal flange, Y2 have double heating element, Y4 have three heating element, the size in the table is the standard specifications, non-standard need to customized.
2.The nozzle default combination cover is black plastic cover, matching the yellow fiberglass cover、iron-nickel-plated cover, the detail specification reference accessories series.
HSY6 series for the sheathed electric heater for hydraulic and lubricating device heating hydraulic oil and lubricants can also be used to heat non-corrosive gas or liquid.
HSY6 sheathed electric heater features:
Electric heater by heating the wick and jacket. High temperature alloy heating wire heating wick as a heat source, the high temperature magnesium oxide powder insulation material, the jacket with high-temperature steel pipes.
Electric heater wick connect with the jacket flange. Jacket will wick and the isolation of the oil is heated heating, replace the electric heater, do not need to let go of the oil in the tank, just out of the heater wick replacement of a new heating wick can, and easy maintenance The large contact area and surface power, electric heater and the heating oil that does not produce carbon, oil is not the local high temperature carbonization. Have the feature of Long life, safe and reliable.
Model | Length | Voltage | Power |
HSY6-2 | 430 | 380V | 2KW |
HSY6-3 | 630 | 380V | 3KW |
HSY6-4 | 720 | 380V | 4KW |
HSY6-5 | 840 | 380V | 5KW |
HSY6-6 | 920 | 380V | 6KW |
HSY6-8 | 1200 | 380V | 8KW |
HSY6-10 | 1400 | 380V | 10KW |
Note: Φ 63 / Φ 108 armor tube material for 304, other specifications non-standard customized.
HS-EX Explosion proof electric heating tube series
Explosion proof electric heating tube with high quality and long life of heating equipment is popular in the international market.heating,keep warm the flow of the liquid gaseous medium . When the heating medium under pressure, the heating tube generate intense heat,let medium temperature live up to the customer’s requirement
Explosion proof electric heating tube usually used in dangerous situation. Flammable and explosive gas, oil blow up when contact spark effects.so adopt this HS-EX Explosion proof electric heating tube in this situtation,the aim is to eliminate the hidden trouble of electric spark to detonate with installing a detonating device at the end of the heater
Application zone :1 Chemical industry,heating chemical materials,drying dust under pressure.
2. Carbon cyanide heating, petroleum crude oil, heavy oil, fuel oil, conducting oil, lubricating oil, paraffin
3. Industrial water, Superheated steam, molten salt, nitrogen gas, water gas and so on
4.Due to the advanced explosion-proof structure, equipment is widely used in chemical, petroleum, natural gas, offshore platforms, ships, mining explosion occasion.
Pictures | Model | Length | Voltage | Power |
| HS-EX1-1.5 | 250 | 220V | 1.5KW |
380V | ||||
HS-EX1-2 | 300 | 220V | 2KW | |
380V | ||||
HS-EX1-3 | 400 | 220V | 3KW | |
380V | ||||
HS-EX2-2 | 300 | 220V | 2KW | |
380V | ||||
HS-EX2-3 | 350 | 220V | 3KW | |
380V | ||||
HS-EX2-4 | 500 | 220V | 4KW | |
380V | ||||
HS-EX2-5 | 600 | 220V | 5KW | |
380V | ||||
HS-EX2-6 | 700 | 220V | 6KW | |
380V | ||||
HS-EX2-9 | 800 | 220V | 9KW | |
380V | ||||
| HS-EX3-5 | 400 | 220V | 5KW |
380V | ||||
HS-EX3-6 | 500 | 220V | 6KW | |
380V | ||||
HS-EX3-9 | 700 | 220V | 9KW | |
380V | ||||
HS-EX3-15 | 1000 | 220V | 12KW | |
380V |
Note: the table above is standard explosion proof electric heating tube, Flange international 115 304 stainless steel material,and we can make as your requirement.
HS-FL flang heaters
1. Flange below must be completely immersed in water, which avoid burn out components, the water is heated should be non-corrosive, the corrosive liquids to be customized.
2. When the pipe surface scale, must be divisible to use, so as not to reduce the efficiency and even cause instant dry, burned out heating tube.
3. The product should be stored in a dry place ,if long-term placement of the insulation resistance dropped to less than one megohm, also can be dried in the oven 200 degrees for several hours(Or components of low-voltage electricity, more than one series of a few hours)so that can restore the insulation resistance.
4.The following table are conventional form,the default of flange material is 302,if has non-standard products to be customized .
Pictures | Flange size | Pipe diameter | Length | Voltage | Power | Combination cover |
| 1″ | Φ8 | 250 | 220V | 1KW | |
300 | 220V | 1.5KW | ||||
1-1/4″ | Φ8 | 250 | 220V | 2KW | ||
380V | ||||||
300 | 220V | 3KW | ||||
380V | ||||||
350 | 220V | 4KW | ||||
380V | ||||||
1-1/4″ | Φ8 | 300 | 220V | 3KW | ||
380V | ||||||
350 | 220V | 6KW | ||||
380V | ||||||
400 | 220V | 9KW | ||||
380V | ||||||
1-1/2″ | Φ8 | 300 | 220V | 3KW | ||
380V | ||||||
350 | 220V | 6KW | ||||
380V | ||||||
400 | 220V | 9KW | ||||
380V | ||||||
Φ10 | 300 | 220V | 3KW | |||
380V | ||||||
350 | 220V | 6KW | ||||
380V | ||||||
400 | 220 | 9KW | ||||
380 | ||||||
2″ | Φ10 | 300 | 220 | 3KW | ||
380 | ||||||
350 | 220 | 6KW | ||||
380 | ||||||
400 | 220 | 9KW | ||||
380 | ||||||
Φ12 | 300 | 220 | 3KW | |||
380 | ||||||
350 | 220 | 6KW | ||||
380 | ||||||
400 | 220 | 9KW | ||||
380 | ||||||
2-1/2″ | Φ12 | 300 | 220 | 6KW | ||
380 | ||||||
400 | 220 | 9KW | ||||
380 | ||||||
500 | 220 | 12KW | ||||
380 | ||||||
Φ16 | 300 | 220 | 6KW | |||
380 | ||||||
400 | 220 | 9KW | ||||
380 | ||||||
500 | 220 | 12KW | ||||
380 |
Note: the above form are regular size, non-standard customized, flange size can be reference accessories series.
Water boiler tube
Model | Flange diameter | Length | Voltage | Power |
HS-KSQ-3KW | Φ64 | 160 | 220V | 3KW |
HS-KSQ-6KW | Φ64 | 240 | 380V | 6KW |
HS-KSQ-9KW | Φ64 | 280 | 380V | 9KW |
HS-KSQ-12KW | Φ64 | 330 | 380V | 12KW |
Model | Flange diameter | Diameter | Voltage | Power |
1# | M12 | Φ8 | 230V | 2KW |
2# | M16 | Φ10 | 230V | 2KW |
Model | Flange diameter | Voltage | Power |
Φ145 | Φ45 | 220V | 2000W |
Φ145 | Φ45 | 380V | 2000W |
Φ200 | Φ45 | 380V | 2500W |
Φ200 | Φ45 | 380V | 2500W |
Wing chip heating tube
Model | Fin size | Pipe diameter | Length | Voltage | Power |
1# | 50X25 | Φ8 | 400 | 220V | 1KW |
2# | 500 | 1.5KW | |||
3# | 600 | 2KW | |||
4# | 700 | 2.5KW | |||
5# | 800 | 3KW | |||
6# | 900 | 3.5KW | |||
7# | 1000 | 4KW |
Model | Fin size | Pipe diameter | Length | Voltage | Power | |
350 | 0.3X7 | Φ16 | 350 | 220/380V | 1100W | 1800W |
400 | 400 | 1200W | 2000W | |||
450 | 450 | 1400W | 2300W | |||
500 | 500 | 1500W | 2500W | |||
550 | 550 | 1700W | 2800W | |||
600 | 600 | 1800W | 3000W |
Corrosive liquid heater
Quartz liquid heater | Specifications | Voltage | Power |
570mm | 220V | 2KW | |
570mm | 380V | 2KW | |
780mm | 220V | 3KW | |
780mm | 380V | 3KW |
Titanium tube | Specifications | Voltage | Power |
600mm | 220V | 2KW | |
600mm | 380V | 2KW | |
800mm | 220V | 3KW | |
800mm | 380V | 3KW |
| Specifications | Voltage | Power |
500mm | 220V | 2KW | |
500mm | 380V | 2KW | |
700mm | 220V | 3KW | |
700mm | 380V | 3KW |