EMERSON Expansion Valve BAE 1 2 3 4 5 6 NW100 R22 407C

Price range: $1.00 through $2.84 ( Not real price )

Emerson BAE‑Series NW100 Balanced‑Port Thermostatic Expansion Valve dedicated for R407C refrigerant. Available models: BAE1NW100, BAE3NW100, BAE4NW100, BAE5NW100, BAE6NW100. Features bi‑flow heat‑pump operation, corrosion‑resistant stainless‑steel power element and hermetic leak‑proof housing, delivers precise superheat control to protect compressors for air‑conditioning & refrigeration systems.

SKU: SC26092570 Category: Brand:
Our products are liked and shared by:

This is an Emerson BAE‑series balanced‑port thermostatic expansion valve (TXV), purpose‑built for R407C refrigerant in air‑conditioning and heat‑pump refrigeration systems. It meters and throttles high‑pressure liquid refrigerant entering the evaporator while maintaining stable superheat.

Product Information

Product TypeThermostatic Expansion Valve (TXV), Balanced‑Port, External Equalized
BrandEmerson
SeriesBAE NW100
Compatible RefrigerantR22 R407C dedicated charge
Available ModelsBAE1NW100, BAE3NW100, BAE4NW100, BAE5NW100, BAE6NW100
RefrigerantSeriesNominal Cooling Capacity (Ton)Charge TypeStatic SuperheatCapillary LengthConnection Type & SizePCN
R22BAE1HCA6A (3.3K)30 in / 0.75 m3/8 ODF × 1/2 ODF S/T063200
R22BAE1-1/2HCA6A (3.3K)30 in / 0.75 m3/8 ODF × 1/2 ODF S/T061954
R22BAE2HCA6A (3.3K)30 in / 0.75 m3/8 ODF × 1/2 ODF S/T061955
R22BAE2-1/2HCA6A (3.3K)30 in / 0.75 m3/8 ODF × 1/2 ODF S/T061956
R22BAE3HCA6A (3.3K)5 ft / 1.5 m1/2 ODF × 5/8 ODF S/T063019
R22BAE4HCA6A (3.3K)5 ft / 1.5 m1/2 ODF × 5/8 ODF S/T065335
R22BAE5HCA6A (3.3K)5 ft / 1.5 m1/2 ODF × 5/8 ODF S/T061964
R22BAE6HCA6A (3.3K)5 ft / 1.5 m1/2 ODF × 5/8 ODF S/T062736
R407CBAE2NW1006A (3.3K)5 ft / 1.5 m3/8 ODF × 1/2 ODF S/T065552
R407CBAE3NW1006A (3.3K)5 ft / 1.5 m1/2 ODF × 5/8 ODF S/T065553
R407CBAE4NW1006A (3.3K)5 ft / 1.5 m1/2 ODF × 5/8 ODF S/T065554
R407CBAE5NW1006A (3.3K)5 ft / 1.5 m1/2 ODF × 5/8 ODF S/T065556
R407CBAE6NW1006A (3.3K)5 ft / 1.5 m1/2 ODF × 5/8 ODF S/T065557
R134aBAE1MC6A (3.3K)30 in / 0.75 m3/8 ODF × 1/2 ODF S/T061967
R134aBAE2MC6A (3.3K)30 in / 0.75 m1/2 ODF × 3/8 ODF S/T062830
R134aBAE3MC6A (3.3K)30 in / 0.75 m1/2 ODF × 3/8 ODF S/T063201
R410ABAE1ZAA6A (3.3K)30 in / 0.75 m3/8 ODF × 1/2 ODF S/T066860
R410ABAE1-1/2ZAA6A (3.3K)30 in / 0.75 m3/8 ODF × 1/2 ODF S/T066861
R410ABAE2ZAA6A (3.3K)30 in / 0.75 m3/8 ODF × 1/2 ODF S/T066863
R410ABAE3ZAA4A (2.2K)5 ft / 1.5 m3/8 ODF × 1/2 ODF S/T066866
R410ABAE3-1/2ZAA4A (2.2K)5 ft / 1.5 m3/8 ODF × 1/2 ODF S/T066868
R410ABAE4-1/2ZAA4A (2.2K)30 in / 0.75 m3/8 ODF × 1/2 ODF S/T066871
R410ABAE6ZAA6A (3.3K)5 ft / 1.5 m1/2 ODF × 5/8 ODF S/T066872
R410ABAE7-1/2ZAA4A (2.2K)5 ft / 1.5 m1/2 ODF × 7/8 ODF S/T066873

Product Features

  • Balanced‑port architecture compensates variable operating pressure from changing ambient, defrost cycles, heat reclaim and shifting evaporator loads for steady superheat regulation
  • Bi‑directional flow performance supports both cooling and heating operation in heat‑pump setups with one single valve unit
  • Corrosion‑resistant stainless‑steel power element prevents premature valve failure from refrigerant‑side corrosion
  • Hermetic leak‑free sealed construction reduces risk of refrigerant leakage
  • Compact form factor to fit tight mechanical room or unit internal mounting spaces
  • External equalization design optimizes performance for evaporators with notable internal pressure drop
  • Factory pre‑charged for R407C refrigerant for direct drop‑in replacement

Application Scenarios

HVAC‑R technicians, system integrators, maintenance contractors and equipment rebuilders select this Emerson BAE‑NW100 TXV for R407C systems facing variable thermal loads.

  1. Residential / light‑commercial air‑to‑water heat pump retrofits: Replace failed expansion valves in existing R407C heat‑pump units requiring bi‑flow control across heating and cooling modes.
  2. Packaged rooftop air‑conditioning units: Service and repair R407C rooftop AC systems exposed to wide outdoor ambient temperature fluctuations.
  3. Medium‑temperature commercial refrigeration display cases: Maintain stable evaporator superheat for display coolers running R407C under shifting product heat‑load conditions.
  4. HVAC equipment rebuild & component‑swap workshops: Drop‑in OEM‑equivalent replacement part for refurbishing legacy R407C cooling assemblies.
  5. Light industrial process cooling units: Stabilise refrigerant metering for process chillers using R407C that experience variable process heat loads.

Additional information

Option

BAE1NW100 2Tons PCN 065552, BAE3NW100 3Tons PCN 065553, BAE4NW100 4Tons PCN 065554, BAE5NW100 5Tons PCN 065556, BAE6NW100 6Tons PCN 065557, Enquiry for more specifications

Reviews

There are no reviews yet.

Be the first to review “EMERSON Expansion Valve BAE 1 2 3 4 5 6 NW100 R22 407C”

    Or   

    Or   

Variation Preview