Electronic expansion valve DPF-T / Ts / S series
Electronic expansion valve DPF-T / Ts / S series
DPF-T / Ts / S series electronic expansion valve is mainly used in refrigeration, air-conditioning and heat pump systems to achieve automatic adjustment of refrigerant flow, make the system operate under the best conditions, and achieve rapid cooling or heating, precise control Moderate energy saving and other purposes. It can also be used for pressure control of the suction pipe.
FEATURES:
* 5-wire or 6-wire coil is optional;
* Applicable for oil-free system;
* Smaller installati on space : low height, small volume , light weight;
* Optimi zed ft ow path design for noise reduction;
* Fast operation, energy saving;
* Applicable for reversible systems like heat pumps: bidirectional flow;
Place of origin: Supplier by China Manfacturer direct-sale .
Order or Inquiry on “Electronic expansion valve DPF-T / Ts / S series” |
Models & Details for “ Electronic expansion valve” |
Electronic expansion valves are designed for use in air conditioning and refrigeration systems or in heat pumps.The valve controls the automatic adjustment of refrigerant flow rate and makes the system work under optimized conditions for the purpose of fast cooling or heating, precisetemperature control and energy saving. The valve can also be used e.g. for suction line pressure controls.These valves provide bidirectional operation to control the refrigerant flow rate in heating or cooling mode.
Features
- Smaller installation space: low height, small size, light weight
- Optimized runner, lower noise
- Fast action and energy saving
- Suitable for reversible systems, such as heat pumps, two-way flow, etc.
- Ts series is more suitable for oil-free systems
General specifications
- Applicable refrigerants: R22, R134A, R404A, R407C, R410A, R507C, etc.
- Capacity range: 3.5 ~ 105kW (R22 nominal capacity)
- Applicable medium temperature: -30 ° C ~ + 70 ° C (power-on rate below 50%)
- Applicable ambient temperature: -30 ° C ~ + 60 ° C (power-on rate below 50%)
- Relative humidity: below 95% RH
- Full open pulse: 500; Open valve pulse: 32 ± 20
- Working pressure: 4.5MPa (45 Bar)
- Certification: UL & CUL, LVD or PED Directive
- Installation method: the coil is facing upward, the central axis of the valve body rotor is perpendicular to the horizontal plane, and the deviation is within ± 15 ° C; the inlet pipe is horizontal, and the outlet pipe is downward
Electrical parameters
- Rated voltage: 12V DC (± 10%), rectangular wave
- Action mode: 4 phase 8 beat permanent magnet stepper motor, direct acting
- Excitation method: 1 ~ 2 phase excitation, unipolar drive
- Excitation speed: 30pps ~ 40pps
- End excitation mode and keep 0,1s ~ 1,0s
- The shortest action time from full open to full close: 13s (40pps)
- Coil current:
- 1.3 ~ 4.5 mm diameter: 260mA / phase (20 ° C)
- 5.5 ~ 6.5 mm diameter: 375mA / phase (20 ° C)
- Coil resistance:
- 1.3 to 4.5 mm diameter: 46 ± 3.7 Ω / phase (20 ° C)
- 5.5 to 6.5 mm diameter: 32 ± 3.2 Ω / phase (20 ° C)
- Coil insulation level: E level
- Protection class: IP 67
Dimensions
Valve series | Coil type | Dimensions [mm] | Order number | ||||
---|---|---|---|---|---|---|---|
A | B | C | D | E | |||
DPF (T01) 1.3C-07 ~ DPF (TS1) 3.2C-01 | PQ-M10 012-000277 | 38.5 | 26.4 | 25.6 | 700 | 600 | DPF-58001 |
DPF (S03) 4.0C-01 ~ DPF (S03) 6.5C-02 | PQ-M03012-000001 | 67.5 | 42.4 | 33 | 700 | 600 | DPF-58002 |
* Rated conditions: Condensing temperature: 38ºC; Evaporating temperature 5ºC; Supercooling OK; Superheat OK
Valve series | Coil type | Dimensions [mm] | ||||
---|---|---|---|---|---|---|
F | G | H | M | N | ||
DPF (T01) 1.3C-07 to DPF (T01) 2.4C-01 | PQ-M10 | 78 | 36 | 30 | 6,35 | 17,35 |
DPF (TS1) 3.0C-01 to DPF (TS1) 3.2C-01 | PQ-M10 | 82 | 40 | 30 | 7,94 | 17,35 |
DPF (S03) 4.0C-01 to DPF (S03) 6.5C-02 | PQ-M03 | 148 | 64,7 | 63,4 | 15,88 | 35,3 |
Flow characteristics
How to purchase “ Electronic expansion valve” |
- The item is available for retail and wholesale;
- The place of origin is in China,when you buy one or two,please consider freight(by air or by sea) into the cost;
- Accept bulk order with Container delivery;
- Please contact us to email: hvac@smartclima.com
General Knowledge on “Electronic expansion valve ” |
Electronic expansion valve for room air conditioner control
The main Characteristics of Series Q EXV: small size, light, the flow path is versatile to handle noise of refrigerant, high reliability and long life.
Download Product Specification
Electronic expansion valve for commerical air conditioner control
The main Characteristics of Series Q EXV: small size, light, the flow path is versatile to handle noise of refrigerant, high reliability and long life.
Download Product Specification
Electronic expansion valve for heat pump control
Series R EXV is mainly used in HP water heater with CO2 to adjust flow of refrigerant automatically. Thus the water heater can always stay at the optimized working conditions with quick heating, precise temperature control, low energy consumption, etc. This valve can only be used in one direction to automatically control the flow under heating condition.
Download Product Specification
Electronic expansion valve for cold chain control
Electronic expansion valve is used in Inverter air conditioning system to adjust flow of refrigerant automatically. Thus the air conditioner can always stay at the optimized working conditions with quick cooling, precise temperature control, low energy consumption, etc. This valve can also be used for other controls. This valve is reversible and can control the flow under either cooling or heating condition.
The main Characteristics of Series Q EXV: small size, light, the flow path is versatile to handle noise of refrigerant, high reliability and long life. Download Product Specification
Enquiry or Reviews
0
/5Based on 0 rating(s)
5 Star
4 Star
3 Star
2 Star
1 Star
0 Star
Reviewed by 02 customer(s)
Leon
Hi,
I am looking at the series R valve, for a domestic hot water heat pump application. The documentation indicates that flow should be from A to B in heating, but I am unable to identify which port is A and which is B. Please could you confirm the port numbering and perhaps provide a schematic of a recomended install?
Thanks
Leon2015-10-09Replyvince
do you have a USA wolesaler of the \”Q\” Series EXV valves?
2014-07-21Reply