Manufacturer: Smarclima Model:XH-W1501 Thermostat Range: -50℃ to 110℃ Thermostat Accuracy: 0.1℃ Power Supply: DC12V/AC220V Output: 1 route electric relay output,capacity=10A For cooling or heating temperature control Size: 78x51mm
Place of origin: China factory sell directly , Sell to worldwide.
Models & Details for “digital Thermostat Module Model XH-W1301 ”
Features 1, the chip technology for higher performance, lower power consumption! 2, the positive and negative elements are designed for embedded panel installation 3, high-speed flash memory chip RAM 4, set the automatic power-off memory 5, the control accuracy of 0.1 degrees Celsius 6, the key buzzer (can be turned off) 7, high temperature alarm buzzer (0-110 degrees set free) 8, hysteresis setting 0.5 onwards, you can control the number of decimal (0.5 to 15.0)
Technical parameters Temperature control range: -50 ~ 110 ℃ Resolution: -9.9 to 99.9 0.1 ℃ when other temperature ranges 1 ℃ Temperature measurement accuracy: 0.1 ℃ Control accuracy: 0.1 ℃ Backlash accuracy: 0.1 ℃ Refresh rate: 0.5 S Input Power: DC / AC 12V Measurement input: NTC (10K 0.5%) Waterproof sensor Output: 1 relay output, capacity = 10A Environmental requirements: -10 ~ 60 ℃ Humidity 20% -85% Size: 78 * 51mm (M3 mounting holes diagonal 75mm.) Power consumption: Quiescent Current: ≤35MA pull current: ≤65MA
Operation “digital Thermostat Module Model XH-W1301”
Connect the power supply and equipment, the controller can be powered to measure the temperature is displayed, press the SET button, the display temperature flashes, press + – to set the desired temperature (hold down the + – quick lift) set When finished, press sET to confirm the return, then the controller automatically executed by setting the relay off! The thermostat is 10A relay outputs to meet a variety of high-power loads, connect the control circuit can be powered for the thermostat, then the display is the ambient temperature,
*The lights, LED and buzzer status description LED: flashes to indicate cooling or heating startup delay, Always indicate the relay is closed Digital Tube: Shows LL sensor opens, follow the instructions to connect the sensor; display HH is beyond the measurement range thermostat will forcibly disconnect relay; high-temperature alarm display — Buzzer: When digital display LL, HH or , buzzer di -di -di -di
Parameter Function Press SET 5 seconds to enter the main menu settings, press the + – Switch P0 … P8 long press SET or automatic confirmation button for 10 seconds without motion controller returns P0 refrigeration, heating mode Press SET 5 seconds display P0, press SET to set the operating mode, press the + – switched to heating mode [H] [C] for cooling mode press SET to return, long press SET or automatic confirmation button for 10 seconds without motion controller carry out Cooling mode: when the temperature measured value ≥ temperature set point relay refrigeration, refrigeration starts; when the temperature measured value ≤ temperature set point – hysteresis, the cooling relay is off, turn off the refrigerator Heating mode: when the temperature set point temperature measurement value ≤ heating relay, heater starts; when the temperature set point temperature measurements ≥ + hysteresis heating relay off, the heater is off P1 hysteresis setting Press SET 5 seconds display P0, press + – Switch to P1, press SET to set back the difference, press + – Set hysteresis 0.5-15, press SET to return after the completion of 10 seconds long press SET or no key motion controller automatically confirm completion Cooling mode: When the temperature measurement value ≥ set value, the relay, refrigeration starts; when the temperature measured value ≤ set value – the difference between the return, the relay off, cooling off. Such as the environment is set at 30 ℃ 25 ℃, hysteresis is set to 2 ℃, after power relay closed cooling starts, when cooling to 23 ℃, the relay off cooling off, this time due to the cooler has been broken open the temperature began to rise back up to the set value when 25 ℃, the relay is closed cooling starts again, so repeated cycle control temperature no higher than 25 ℃ Heating mode: When the temperature measurement value ≤ set value, the relay, the heater starts; when the temperature measured value ≥ set value + return difference, the relay off, the heater is turned off. Such as the environment is 10 ℃ setting is 25 ℃, hysteresis is set to 2 ℃, the relay is closed after power heater starts, when heated to 27 ℃, the relay off the heater turned off, this time due to the heater has been broken open the temperature begins to drop, the moment when the set value dropped 25 ℃, the relay is closed heater starts up again, so repeated cycle control temperature not lower than 25 ℃ P2 limit the maximum temperature settings: To avoid misuse of others led to the setting temperature is too high risk that the thermostat is set to a maximum limit function limits the maximum temperature set point thermostat-controlled setting range Press SET 5 seconds display P0, press + – Switch to P2, press SET to set the maximum limit, press + – to set up the set temperature, the maximum is 110, according to a SET return is completed, long press SET or 10 no keystrokes second controller automatically confirm completion For example: Set the maximum temperature set point is 60 to 60 ℃ can only be set if you want a higher temperature set point temperature to expand the scope, you need to adjust the upper limit setting. P3 lowest temperature setting limit: To avoid misuse of others lead to the occurrence of ice blocking temperature is too low, this thermostat has a lower limit on the lowest setting function, defining the minimum temperature set point thermostat-controlled setting range Press SET 5 seconds display P0, press + – Switch to P3, press SET to set a minimum limit, press + – to set the minimum temperature can be set to a minimum value of -50, press SET to return after the completion of, or long press SET 10 seconds, the controller automatically without keystrokes confirm completion For example: Set the minimum temperature set point 2 can only be set to 2 ℃ temperature set point if you want to expand the scope of lower temperatures, you need to change the setting lower limit. P4 temperature correction When measuring the temperature and the standard temperature deviations due to user hardware or have special needs, you can use this function to correct temperature = temperature correction after correction + correction before the effective range of -7.0 to 7.0 Press SET 5 seconds display P0, press + – Switch to P4, press SET to correct, press + – to set the correction value, press SET to return upon completion, or long press the SET button for 10 seconds without motion controller automatically confirm completion For example, the normal display is 25 degrees; temperature correction for 0:00 show 25 degrees; 26.5 degree temperature correction to show 1.5; temperature correction to display 23.5 -1.5; P5 delayed start time units: minutes When the cooling or heating needs work delay, delay function can be opened to protect the life of the equipment Press SET 5 seconds display P0, press + – Switch to P5, press SET to set the delay start time is in minutes, press the + – Set 0-10 minutes, press SET to return after the completion, or 10 seconds long press SET no keystrokes controller automatically confirm completion Cooling mode: the first powered, rear if the current temperature ≥ set value, the cooler will not start cooling, run the set delay time starts immediately Heating mode: the first powered, if the current temperature ≤ set value, the heater does not start immediately heating, you need to run to set the delay time after start Downtime cooler or heater starts between two adjacent delay start time is greater than the set value, the cooler immediately start; Shutdown cooling or heating between two adjacent launch delayed start time lapse is less than the set value, the need to start again after finished running cooler set delayed start time for the device to start. Delay time is counted down moments. For example, the state set the delay under refrigeration for 5 minutes after boot cooler startup delay, five minutes after opening the refrigerator to reach the desired temperature when cooling is stopped, then the start time, the next time the refrigerator immediately start the timer is complete work unfinished end timing to wait timed to work, delay in the LED blinks Delay start is set to 0 equals off delay feature P6 key tone switch Press SET 5 seconds display P0, press + – Switch to P6, press the SET button to set the sound is turned on, press + – to set on / off, press SET to return completed, or long press SET button for 10 seconds without motion control automatically confirm completion Buzzer switch points on / off button is set on for the key issue with the sound drops when action is set to shut off that buzzer, button-free sound P7 temperature alarm Press SET 5 seconds display P0, press + – Switch to P7, press SET to display on / off (set to shut off the second function) is set to on and press the SET temperature alarm can be set point temperature, press + – Set 0 to 110, after the completion of press SET to return, or long press SET button for 10 seconds without motion controller automatically confirm completion High temperature alarm setting range is 0-110 times or shut off function, arriving after the buzzer beeps rapid temperature alarm, and forced disconnect relay For example, when we give a liquid or space heating to 40 degrees, 80 degrees set a dangerous temperature, work process due to force majeure outside temperature is above 80 degrees cause dangerous temperature, high temperature alarm relay started off buzzer breath alarm, alert staff to take timely and appropriate measures to recoup their losses! Alarm temperature can be set according to actual needs, you do not want this function to the temperature set to off, note that when the temperature returns to normal automatic discharge temperature alarm thermostat work properly P8 restore factory settings Some man-made causes internal thermostat settings chaos, one to set a time-consuming, this feature is available at this time restore the factory settings, specific methods for Press SET 5 seconds display P0, press + – Switch to P8, press SET to on or off, on to restore the factory settings, off to no action, press SET to return upon completion, or 10 seconds long press SET bell no keystrokes controller automatically restore the factory set parameters in the table below
Buying Guide to “digital Thermostat Module Model XH-W1301”
The Digital Thermostat Module Model XH-W1301 is available for retail and wholesale;
The place of origin is in China,when you buy one or a small quantity,please consider freight into the cost;
Accept bulk order with Container delivery;
Please contact us to email: econtrol@smartclima.com or sale@smartclima.com ,we can supply a favourite item you need.
Be the first to review “digital Thermostat Module Model XH-W1301”