Sale!

Aluminium Volume Control Damper

Sell Aluminium Volume Control Damper .I,dimension can be customized.

Place of Origin:

  • Direct-sale by China Manufacturer.
  • Sell to worldwide, Ship by air plane or by sea boat;

 Order Or Inquiry On “Aluminium Volume Control Damper”

Models and Details for “Aluminium Volume Control Damper ”

This damper is made from aluminium,has good performance of anti corrision(If you need,we can also do steel or stainless steel damper).Available with shape of rectangular and circular.Can be powder painting.A Volume Control Damper (VCD) is a valve that stops or regulates the air flow volume inside a ventilation duct, VAV box, air handler units, or in other air handling equipment. A VCD may be used to cut off central air conditioning to an unused room, or to regulate it for room-by-room temperature and climate control.Its operation can be by manual or automatic(motorized). Manual dampers are turned by a handle on the outside of a duct.Automatic dampers are used to regulate airflow constantly and are operated by electric Actuator, in turn controlled by a thermostat or building automation system.

Size: customized.
Min. Order: 1 unit.
Place of origin: China , Sell to worldwide.

Features

(1) Made from aluminium,has good performance of anti corrision.(Sheet steel or Stainless steel is available if you required),it can be powder painting.
(2) Same size with the national popular ventilation ducts specified rectangular or circular duct size.
(3) Blade is divided into different types, it is always used as regulator in ventilation, air conditioning, air purification system.
(4) Good sealing performance, the relative amount of air leakage is around 5% only,so ,it has good regulation performance.

Volume Control Damper Aluminium Volume Control Damper 2

Volume Control Damper VCD-AD

Model: VCD-AD
* Material: Aluminum
* Feature:
* Frame thick: 1 .0mm, blade thick: 1 .0mm .
*  Used with diffusers and grilles.
* The blades can be opened and closed simultaneously end their angle is adjustable mechanically with a screw driver or fitted handle to control the volume of airflow.
” Size can be customized according to the application.

Volume Control Damper Aluminium Volume Control Damper 4

Volume Control Damper VCD-AG

Model: VCD-AG11AG2
* Material: Aluminum
* Feature:
* Frame thick: 1.0mm. blade thick: 1.0mm.
* Used with diffusers and grilles.
* The blades can be opened and closed simultaneously and their
angle Is adjustable mechanically with a screw driver or fitted handle to control the volume of airflow.
* Size can be customized according to the application.

Volume Control Damper Aluminium Volume Control Damper 6

Volume Control Damper VCD-B
Model: Volume Control Damper VCD-B

* Material:Aluminum
*Feature:
* Frame thick: 1.0mm, blade thick:1.Omm.
* Used with grille and diffuser.
* The blades of which are opened and closed simultaneously and their angle is adjustable by screw driver to control the volume of airflow.
* Size can be customised according to application.

 How to purchase “Aluminium Volume Control Damper”

  • The item  is available for retail and wholesale;
  • The place of origin is in China,when you buy one or two,please consider freight(by air or by sea) into the cost;
  • Accept bulk order with Container delivery;
  • Please contact us online (click here) Or send inquiry message to our email:  ventilation@smartclima.com

General Knowledge on “Aluminium Volume Control Damper”

Volume Control Damper,also called air volume control valve,VCD in brief,is a device by adjusting the opening and closing angle of the blades to control air flow volume, mainly installed in rectangular or circular duct ventilation system. Widely used HVAC projects and systems, to adjust air flow accurately.It is one of the key devices to achieve a variety of environments under control ventilation mode. Its main feature is manually adjustable, flexible operation, low noise, leaking a small amount (closed type leakage <0.5%) Operating temperature region wide, reliable structure, safe and convenient.

Volume Control Damper structural features
(1) the air flow control valve in the unity of the whole blade width four sizes, leaf-shaped diamond-shaped double blades, vanes between soft lap, so good airtight performance.
(2) air volume control valve body architecture After 2 mm cold rolled galvanized sheet molding, carbon dioxide gas welding or welding by ordinary Q235 plate processing; blades with 1 mm cold rolled galvanized sheet for corrugated, two synthetic spot-square shaft inserted, or 2 mm G235 steel cold forming, punching chip interpolating axes or welding circular shaft.
(3) The damper is divided into by manual,by electric(motorized type),and according to the materials used,it can be divided : iron, galvanized sheet, aluminum plate, stainless steel (body structure and size specifications are same with different material).