General Knowledge on “Air conditioning outdoor unit Axial Flow Fan Blade”
What is the role of t”Air conditioning outdoor unit Axial Flow Fan Blade”? The fan of the air conditioner is used to dissipate heat from the condenser to improve the heat exchange efficiency of the condenser. If there is no outdoor unit fan or it is not working, the effect of the air conditioner will be greatly reduced and cause system pressure protection.
Why does Axial Flow Fan Blade broken? In the air conditioner I have repaired, all the accidents of the fan blade: Both fans are subjected to external forces; Some items enter the fan. Such as wooden sticks; The fan rubs against the inside. Such as the case;Winter water freezes after entering.After finding the causes, deal with the cause and then replace the fan blade. Note: The regular fan blade is balanced and has a balanced counterweight. After the new fan blade is installed, if there is obvious vibration after starting the machine, it is unqualified. It costs electricity, is noisy, and is easily damaged.
How to remove the fan blades on the air conditioner outdoor unit? Remove the front panel of the external unit, turn off the fan blade, and fix the nut on the motor shaft to remove the fan blade.
What should I do if the air conditioner outside the fan blows off a leaf now? Air-conditioning Axial Flow Fan Blade have a dynamic balance when designing. A small fan blade will seriously affect performance and noise, and there are safety hazards . It is necessary to find an air conditioner for replacement after replacement. This part is not expensive to replace.
What should I do when the air conditioner cross-flow fan speed is slow Reasons and solutions for the slow rotation of the air-conditioner external fan: 1. The heat sink has a lot of dirt. It is recommended to clean the aluminum fins of the heat sink first. 2, the cooling fan motor is aging or resistance, and the engine of the cooling fan motor is added with oil. 3, the cooling fan motor starts a small capacitor (square, a few dollars a) for a new one.
I’m trying to find a condenser fan blade for the ydk-35D-4c motor in my ptac heat pump. It is a older model klimaire unit and my fan blade broke and I’m having a hard time finding a fan blade to fit cause I don’t know the shaft size. The link below looks like the exact fan as mine but I’m unsure of shaft size.