3-way heat reclaim valve for air conditioner system

Price range: $0.83 through $3.66 ( Not real price )

Supply 3-way heat reclaim valve for air conditioner system,exported by China manufacturer. It is a valve used to regulate the indoor and outdoor circulating air flow of air-conditioning. It is usually used for the heat recovery function in air-conditioning systems.It can improve the efficiency of the indoor air-conditioning system.Suit for refrigerant R22,R134,R407C,R410.

Two models: SHF-11-44 (with or without coil) and SHF-20S-56 (with or without coil).For specification,please refer to the below details.

GTIN: 16204000804687 SKU: SC18060050 Category:
Our products are liked and shared by:

Supply “3-way heat reclaim valve for air conditioner system” as introduced in the following article.Smartclima is professional to supply various of air conditioner parts ,including 3-way and 4-way heat reclaim valves,to explore more types or models,please send enquiry message to us.

Models and Details for “3-way heat reclaim valve for air conditioner system”

(The following size means inner diameter)

Model SHF-11-44 without coil

TECHNICAL DATA of Model SHF-11-44:
1.Max.operative 4P:3.1MPa;
2.Min.operative 4P:0.34MPa;
3.Internal leakage: <2000ml/min
(0.98MPa,the TEMP of valve body is 70℃);
4.Air tightness: 4.2MPa;
5.Lowest operative voltage: under 85% of rated voltage;
6.Hydraulic strength: 6.3MPa;
7.Min. burst pressure: 17.5MPa;
8.Max.working pressure: 4.2MPa;
9.Life: 20000 cycles;
10.Refrigerant temperature: -25℃-+100℃;
11.Rated voltage: AC 220-240V;
12.Frequency: 50/60Hz;
13.Nominal capacity: R22 11KW.
14. Service: Refrigerant R22. R407C. R410A.

Model SHF-11-44 without coil

air conditioner part Model SHF-11-44 without coil

drawing and data sheet for Model SHF-11-44 without coil

Model SHF-11-44 with coil

TECHNICAL DATA of Model SHF-11-44:
1.Max.operative 4P:3.1MPa;
2.Min.operative 4P:0.34MPa;
3.Internal leakage: <2000ml/min
(0.98MPa,the TEMP of valve body is 70℃);
4.Air tightness: 4.2MPa;
5.Lowest operative voltage: under 85% of rated voltage;
6.Hydraulic strength: 6.3MPa;
7.Min. burst pressure: 17.5MPa;
8.Max.working pressure: 4.2MPa;
9.Life: 20000 cycles;
10.Refrigerant temperature: -25℃-+100℃;
11.Rated voltage: AC 220-240V;
12.Frequency: 50/60Hz;
13.Nominal capacity: R22 11KW.
14. Service: Refrigerant R22. R407C. R410A.

Model SHF-11-44 with coil

Model SHF-20S-56 without coil

TECHNICAL DATA of Model SHF-20S-56:
1.Max. operative 4P: 3.1MPa.
2.Min. operative 4P: 0.34MPa.
3.Internal leakage: <4000 ml/min(0.98 MPa, valve body TEMP.=70℃).
4.Lowest operative voltage: 85% of rated voltage.
5.Air tightness: 4.2MPo.
6.Hydraulic strength: 6.3MPa.
7.Min. burst pressure: 17.5MPa.
8.Refrigerant temperature: -25℃~+120℃.
9.Max. working pressure: 4.2MPa.
10.Rated voltage: AC220-240V.
11.Frequency: 50/60Hz.
12.Nominal capacity: R22 20kW.
13.Life: >20000 cycles.
14. Service: Refrigerant R22 R407C R410A.

Model SHF-20S-56 without coil

air conditioner part SHF-20S-56 without coil

3-way heat reclaim valve for air conditioner system 1

Model SHF-20S-56 with coil

TECHNICAL DATA of Model SHF-20S-56:
1.Max. operative 4P: 3.1MPa.
2.Min. operative 4P: 0.34MPa.
3.Internal leakage: <4000 ml/min(0.98 MPa, valve body TEMP.=70℃).
4.Lowest operative voltage: 85% of rated voltage.
5.Air tightness: 4.2MPo.
6.Hydraulic strength: 6.3MPa.
7.Min. burst pressure: 17.5MPa.
8.Refrigerant temperature: -25℃~+120℃.
9.Max. working pressure: 4.2MPa.
10.Rated voltage: AC220-240V.
11.Frequency: 50/60Hz.
12.Nominal capacity: R22 20kW.
13.Life: >20000 cycles.
14. Service: Refrigerant R22 R407C R410A.

3-way heat reclaim valve for air conditioner system 2

Solenoid coil only:

 

solenoid valve for heat reclaim valve

Voltage: AC220-240V. Two sizes with diameter 11.2mm and 5.2mm.

Additional information

Weight 0.75 kg
Dimensions 25 × 16 × 8 cm
Option

SHF-11-44 without coil, SHF-11-44 with coil, SHF-20S-56 without coil, SHF-20S-56 with coil, Solenoid coil only (Remark 220V or 110V when enquiry)

Reviews

There are no reviews yet.

Be the first to review “3-way heat reclaim valve for air conditioner system”