logo

Month: September 2019

Air deflector for ceiling air grille

Air deflector for ceiling air grille 1

Air deflector for ceiling air grille 3

Order or Inquiry on below “Air deflector for ceiling air grille”

Air deflector for ceiling air grille 5Air deflector for ceiling air grille 7Air deflector for ceiling air grille 9Air deflector for ceiling air grille 11Air deflector for ceiling air grille 13Air deflector for ceiling air grille 15

4 sizes for choose: Long 54cm,86cm,94cm,112cm

How to order “Air deflector for ceiling air grille”
  • The  item  is available for retail and wholesale;
  • The item takes large packing dimension,therefore,takes much volume weight.The place of origin is in China,when you buy one or two,please consider freight(by air or by sea) into the cost;
  • Accept bulk order with Container delivery;
  • Pls indicate us the quantity you need,so that we can calculate the shipping charges;
  • For purchasing or other more requirements, Please contact us to email: [email protected]

Order or Inquiry on above “Air deflector for ceiling air grille”

 

Air conditioning compressor starting capacitor

Air conditioning compressor starting capacitor 17

Air conditioning compressor starting capacitor 19

Order or Inquiry on below “Air conditioning compressor starting capacitor”

Description: Air conditioning capacitor 20 25 30 35 45 50 75UF CBB65 compressor air conditioning starting capacitor 450V
The capacitors shown in below article are suitable for Gree air conditioner, Midea air conditioner, Haier air conditioner, Daikin air conditioner, Chigo air conditioner, Oaks air conditioner, Hisense air conditioner, Mitsubishi air conditioner, Panasonic air conditioner, Galanz air conditioner. . . . . . and other brand air conditioner.


Air conditioning compressor starting capacitor 20uf 450VAir conditioning compressor starting capacitor 25uf 450VAir conditioning compressor starting capacitor 30uf 450VAC Outdoor unit compressor starting capacitor 35uf 450VAir conditioning compressor starting capacitor 40uf 450Voutdoor unit compressor starting capacitor 45uf 450VCompressor starting capacitor 50uf 450V starting capacitor 60uf 450VSPLIT Air conditioning compressor starting capacitor 75uf 450V

How to order “Air conditioning compressor starting capacitor”
  • The  item  is available for retail and wholesale;
  • The place of origin is in China,when you buy one or two,please consider freight(by air or by sea) into the cost;
  • Accept bulk order with Container delivery;
  • Pls indicate us the quantity you need,so that we can calculate the shipping charges;
  • For purchasing or other more requirements, Please contact us to email: [email protected]

Order or Inquiry on above “Air conditioning compressor starting capacitor”

 

General Knowledge on “Air conditioning compressor starting capacitor ”
  • Why do air conditioner compressors start with capacitors?
    Because the single-phase current flowing through a single -phase motor cannot generate a rotating magnetic field , a capacitor is needed to separate the phases, so that the current in the two windings produces a phase difference of approximately 90 , to generate a rotating magnetic field .
    There is a starting coil inside the starting capacitor motor , which will work when starting.
    Generally, a single-phase current flowing through a single-phase AC motor winding cannot generate a rotating magnetic field , and therefore various single-phase motors need to have their own special structure, and change a magnetic field having no rotating property into a magnetic field having a rotating property.
    Start capacitive formula: Start capacitive phase-shifting effect of the current flowing through the two filter windings produce about 90 degrees of phase difference , thereby changing the magnetic field is a rotating magnetic field. The refrigerator compressor is equipped with a starting capacitor for the motor to generate a rotating magnetic field and enhance the starting force instead of “regulating”.
    Another example is the cover pole type: the cover pole short circuit ring has a phase difference between the magnetic flux generated by the short-circuit ring portion and the pole surface without the short-circuit ring portion , and the magnetic field on the magnetic pole surface becomes a continuous movement from the uncovered portion to the covered portion. Rotating the magnetic field. Another example motor phase resistance: For the main winding starting current and a secondary winding starting current
    There is a phase difference in time, the main winding is wound by a thicker wire and has a larger number of turns, which is embedded in the outer layer of the stator slot; the secondary winding is wound by a thinner wire and has fewer turns, and is embedded in the inner layer of the stator slot. . The main winding has a small resistance value and a large inductive reactance value, and the secondary winding has a large resistance value and a small inductive reactance value. When the current passes through the two windings, it becomes a two-phase current with a phase difference, and the starting electromagnetic torque is generated . After the motor is started, the secondary winding circuit is disconnected by the relay switch (heavy hammer type or ptc), and the motor is operated by the main winding. 90% of the refrigerator compressor is the use of this split-phase motor, no configuration start capacitor device.
  • The starting capacitor for the air conditioner compressor can be checked by the high blocking of the multimeter.1. When the normal capacitor is detected, the hands will swing to the right first, and then slowly return to the starting position on the left side (the resistance is infinite).2. When detecting capacitors:

    (1) If the needle does not move, it indicates that there is an open circuit inside the capacitor.} If the needle swings to the right to zero ohm position, it will not return, indicating that there is a short circuit in the capacitor;

    (2) After the hands are swung to the right, they cannot be returned to the infinite position of the resistor, indicating that the capacitor is leaking;

    (3) The angle at which the hands swing to the right is small, indicating that the capacity of the capacitor has decreased.

    In the above cases, the capacitors under test can no longer be used.

  • The starting capacitor of the compressor of the air conditioner is broken, the outside machine does not move.
    In this way, the capacitance of one air conditioner compressor is broken, the outside machine does not move, the fan starts to move for a few seconds and stops, it does not move, the indoor unit is normal, and the external machine has no voltage. I changed the compressor starting capacitor. no problem, also moved the fan, compressor no problem …expand
    Air conditioning capacitor is broken, such a situation, the following method may try to reduce this situation:
    1, the air conditioner compressor capacitor is mounted in the outdoor unit. Since the high temperature of the outdoor machine ( temperature + condenser distributed temperature), therefore, the use of longer years capacitor device, the electrolytic solution is easy to dry, fail.
    2. The capacitor of the air conditioner compressor is easy to dry and fail, which is a common fault. When replacing capacitors, be sure to use high-quality capacitors. [The capacity must be the same, and the withstand voltage is not lower than the original standard].

Multifunction Home Appliance Cleaning Machine

Multifunction-Home-Appliance-Cleaning-Machine

air conditioner cleaning,washing,maintenance and comfort improvementMultifunction Home Appliance Cleaning Machine 21Sterilizing-machine-01AC-High-temp-Cleaning-1Cleaning-sterilizing-01Multifunction Home Appliance Cleaning Machine 23all-in-one-banner-1AC-washing-bag-1dust-cleaning-and-suction-label-1air-speed-and-temperature-label-1interior-inspector-label-1air-filter-label-1auxiliary-kit-banner-1Robot-Cleaning-banner-1Rotary-brush-Cleaning-banner-1Multifunction Home Appliance Cleaning Machine 25Shaft-Cleaning-banner-1Duct-Sterilizing-banner-1ozone-sterilizing-label-1

Multifunction Home Appliance Cleaning Machine 27Item:Multifunction Home Appliance Cleaning Machine

Brief Description: It is a 3 in 1 home appliance maintenance equipment,including the function of producing high pressure cold water,high pressure&high temperature hot water,high pressure&high temperature steam.

Usage:to clean and disinfect home appliance,including air conditioner,water heater,fridge,washing machine,range hood,etc;

Manufacturer: Smartclima Co.,Ltd. ;  Place of origin: China , Sell to worldwide

Order or Inquiry on “Multifunction Home Appliance Cleaning Machine”
Details for Multifunction Home Appliance Cleaning Machine

Voltage input: 220V; Heat function: 4000W; Cold water function: 80W; Steam function: 4000W;Cleaning Pressure: 0psi-115psi;
Machine box size: 42X28X25cm; Net weight: 9kg; Outlet pipe: 300cm; Inlet pipe: 150cm;Power cord: 130cm;

  • Multi-function function;more application;more powerful;
  • Multi-function,Can clean air conditioners,fridge,washing machine,electrical water heater,water dispenser,range hood,solar water heater,and other home appliance.
  • Produce high temperature&high pressure steam;
  • Produce high pressure cold water,high pressure hot water;
  • Water pressure reachs 6Bar,no leak,to let you remove the accumulated dust easily;
  • Steam pressure reachs 6Bar,no leak,enough to melt and flush away oily material dust;
  • Pressure can be adjustable;
  • Water status can be adjustable,Adjust Water status to umbrella shape to do chemical liquid cleaning spray;

√ Multi-function. It is 3 in 1 machine,the machine can poduce high pressure normal temperature water,high pressure &high temperature hot water,high pressure steam;temperature and pressure can be adjusted;
√ Multi-application.It not only can clean air conditioner,but also can clean fridge,washing machine,electrical water heater,solar water heater,water dispenser,range hood, and other home appliance;

Multifunction Home Appliance Cleaning Machine 29 Multifunction Home Appliance Cleaning Machine 31 Multifunction Home Appliance Cleaning Machine 33

Operation and Warning

Notice & Warning:
1,The power supply used for this machine is 220V single-phase power supply. Because this machine is used in a humid environment,therefore,the machine must be used with a grounded power cord for safe purpose.
2,Check whether the “Leakage Protection Plug” works good or not before every operation. (Checking way: after power on, press down the key of “RESET”,the power indicator lights; Then press down the key of “TEST”(the yellow key), the power indicator extinguish; Finally,press down the key of “RESET” again,and then can operate normally).If the Leakage Protection Plug button does not work properly, stop using the machine and change to be a good “Leakage Protection Plug”.
3.Very important ! Don`t switch on “Start Heating” if water doesn`t spray out;
4.Must switch to “Stop Heating” if stop using hot water or steam;
5.Don`t continue heating after switch off “Pressure Regulating”;
6,Don`t suck dirty water;
7,Don`t suck hot water( >50℃);
8,Drain out water after working,and keep dry in the box;

Machine parameters:
220V; 16A plug;
Heating function: 4000W;
Pump: 80W;
Max. steam pressure: 0.6Mpa;
Max,water pressure: 0.8Mpa

Operation Manual
How to spray out pressure normal-temperature water?
Immerge inlet pipe`s filter into water, switch on “Pressure Regulating” to L, Press “Water Gun Switch” one time (the Indicator of “Cleaning” lights), and then Switch to “Cold/Hot water”, wait some seconds to spray out pressure water;
How to spray out pressure high-temperature water?
Continue from the step of spraying “pressure normal-temperature water”, when sprays out water, switch to “Start Heating”, wait some seconds to spray out pressure hot water; If don`t use hot water,must switch to “Stop Heating”.
 How to spray pressure steam?
Immerge inlet pipe`s filter into water, switch on “Pressure Regulating” to L, Press “Water Gun Switch” one time (the Indicator of “Cleaning” lights), Switch to “Impulse/Steam” until to spray out water, and then Switch to “Start Heating”, wait some seconds to spray out pressure hot steam; If don`t use steam, must switch to “Stop Heating”.
!!! Very important thing:
Don`t switch on “Start Heating” if water doesn`t spray out;
Must switch to “Stop Heating” if stop using hot water or steam;
Don`t continue heating after switch off “Pressure Regulating”;

Buying Guide to “Multifunction Intelligent Home Appliance Cleaning & Disinfection Machine”
  • The Multifunction Intelligent Home Appliance Cleaning & Disinfection Machine listed above is available for retail and wholesale;
  • The place of origin is in China,when you buy one or a small quantity,please consider freight into the cost;
  • Accept bulk order with Container delivery;
  • Contact [email protected] for more details and prices.

Cross flow fan,Air conditioning internal fan blade

Cross flow fan,Air conditioning internal fan blade 35

Cross flow fan,Air conditioning internal fan blade 37

Order or Inquiry on below “Cross flow fan,Air conditioning internal fan blade”

Cross flow fan,Air conditioning internal fan blade

Cross flow fan,Air conditioning internal fan blade 39Cross flow fan,Air conditioning internal fan blade 41

The color of the blades in the picture is for reference only, subject to the actual color of the goods received !

Brand: Gree, Midea, Panasonic, Chigo, TCL, Galanz, Changhong, etc.

Size explanation:

The “φ” coincidence represents the “wind wheel diameter”

The “L” conforms to the “effective length of the blade”

The lengths of L1 and L2 are generally standard.

There are two ways to fix: one is external fixation (outer teeth), and the other is internal fixation (internal teeth)

How to order “Cross flow fan,Air conditioning internal fan blade”
  • The  item  is available for retail and wholesale;
  • The item takes large packing dimension,therefore,takes much volume weight.The place of origin is in China,when you buy one or two,please consider freight(by air or by sea) into the cost;
  • Accept bulk order with Container delivery;
  • Pls indicate us the quantity you need,so that we can calculate the shipping charges;
  • For purchasing or other more requirements, Please contact us to email: [email protected]

Order or Inquiry on above “Cross flow fan,Air conditioning internal fan blade”

General Knowledge on “Cross flow fan,Air conditioning internal fan blade ”
  • Why does Air conditioner indoor unit cross-flow fan not turn when it is low-grade?
    1,Circuit board problem,
    2,The motor shaft is out of oil. Unpack and add butter.
  • Why does the air conditioning cross-flow fan become noisy?
    There are several reasons as follows:
    1. It may be that too much dust and other dirt accumulate on the fan, resulting in an imbalance.
    2.The left support shaft friction after a little wear
    3.The motor abnormal sound
    4. perfusion fan dynamic balance is not good
  • How to disassemble the air conditioner indoor unit cross flow fan?
    First remove the indoor unit panel and the face frame. Then remove the water tray and remove the electrical control components and the sensor and other connected power controls. Then remove the screws at both ends of the evaporator, carefully lift the evaporator enough to take out the cross-flow wind wheel (in principle, remove the evaporator after removing the fluorine, so simple), remove the plastic motor cover, cross-flow wind wheel and plastic seal The motor can be taken out at the same time to the right to withdraw the left side of the wind turbine shaft from the bearing housing.
    The installer is the opposite.

Air conditioning outdoor unit Axial Flow Fan Blade

Air conditioning outdoor unit Axial Flow Fan Blade

Air conditioning outdoor unit Axial Flow Fan Blade

Order or Inquiry on below “Air conditioning outdoor unit Axial Flow Fan Blade ”

Air conditioning outdoor unit Axial Flow Fan Blade AC outdoor machine shaft flow wind leafAC outdoor wind turbine fan bladeAir conditioning outdoor unit Axial Flow Fan Blade 43Air conditioning outdoor unit Axial Flow Fan Blade 45Air conditioning outdoor unit Axial Flow Fan Blade 47Air conditioning outdoor unit Axial Flow Fan Blade 49Air conditioning outdoor unit Axial Flow Fan Blade 51Air conditioning outdoor unit Axial Flow Fan Blade 53Air conditioning outdoor unit Axial Flow Fan Blade 55Air conditioning outdoor unit Axial Flow Fan Blade 57Air conditioning outdoor unit Axial Flow Fan Blade 59Air conditioning outdoor unit Axial Flow Fan Blade 61Air conditioning outdoor unit Axial Flow Fan Blade 63Air conditioning outdoor unit Axial Flow Fan Blade 65Air conditioning outdoor unit Axial Flow Fan Blade 67Air conditioning outdoor unit Axial Flow Fan Blade 69Air conditioning outdoor unit Axial Flow Fan Blade 71Air conditioning outdoor unit Axial Flow Fan Blade 73Air conditioning outdoor unit Axial Flow Fan Blade 75Air conditioning outdoor unit Axial Flow Fan Blade 77Air conditioning outdoor unit Axial Flow Fan Blade 79Air conditioning outdoor unit Axial Flow Fan Blade 81Air conditioning outdoor unit Axial Flow Fan Blade 83Air conditioning outdoor unit Axial Flow Fan Blade 85Air conditioning outdoor unit Axial Flow Fan Blade 87Air conditioning outdoor unit Axial Flow Fan Blade 89Air conditioning outdoor unit Axial Flow Fan Blade 91Air conditioning outdoor unit Axial Flow Fan Blade 93Air conditioning outdoor unit Axial Flow Fan Blade 95Air conditioning outdoor unit Axial Flow Fan Blade 97Air conditioning outdoor unit Axial Flow Fan Blade 99Air conditioning outdoor unit Axial Flow Fan Blade 101Air conditioning outdoor unit Axial Flow Fan Blade 103Air conditioning outdoor unit Axial Flow Fan Blade 105Air conditioning outdoor unit Axial Flow Fan Blade 107Air conditioning outdoor unit Axial Flow Fan Blade 109Air conditioning outdoor unit Axial Flow Fan Blade 111

How to order “Air conditioning outdoor unit Axial Flow Fan Blade ”
  • The  item  is available for retail and wholesale;
  • The item takes large packing dimension,therefore,takes much volume weight.The place of origin is in China,when you buy one or two,please consider freight(by air or by sea) into the cost;
  • Accept bulk order with Container delivery;
  • Pls indicate us the quantity you need,so that we can calculate the shipping charges;
  • For purchasing or other more requirements, Please contact us to email: [email protected]

Order or Inquiry on above “Air conditioning outdoor unit Axial Flow Fan Blade ”

 

General Knowledge on “Air conditioning outdoor unit Axial Flow Fan Blade ”
  • What is the role of t”Air conditioning outdoor unit Axial Flow Fan Blade”?
    The fan of the air conditioner is used to dissipate heat from the condenser to improve the heat exchange efficiency of the condenser. If there is no outdoor unit fan or it is not working, the effect of the air conditioner will be greatly reduced and cause system pressure protection.
  • Why does Axial Flow Fan Blade broken?
    In the air conditioner I have repaired, all the accidents of the fan blade:
    Both fans are subjected to external forces;
    Some items enter the fan. Such as wooden sticks;
    The fan rubs against the inside. Such as the case;Winter water freezes after entering.After finding the causes, deal with the cause and then replace the fan blade.
    Note: The regular fan blade is balanced and has a balanced counterweight. After the new fan blade is installed, if there is obvious vibration after starting the machine, it is unqualified. It costs electricity, is noisy, and is easily damaged.
  • How to remove the fan blades on the air conditioner outdoor unit?
    Remove the front panel of the external unit, turn off the fan blade, and fix the nut on the motor shaft to remove the fan blade.
  • What should I do if the air conditioner outside the fan blows off a leaf now?
    Air-conditioning Axial Flow Fan Blade have a dynamic balance when designing. A small fan blade will seriously affect performance and noise, and there are safety hazards . It is necessary to find an air conditioner for replacement after replacement. This part is not expensive to replace.
  • What should I do when the air conditioner cross-flow fan speed is slow
    Reasons and solutions for the slow rotation of the air-conditioner external fan:
    1. The heat sink has a lot of dirt. It is recommended to clean the aluminum fins of the heat sink first.
    2, the cooling fan motor is aging or resistance, and the engine of the cooling fan motor is added with oil.
    3, the cooling fan motor starts a small capacitor (square, a few dollars a) for a new one.