Supply materials for Condensate removal system for air conditioner system

 

Condensate Drain Pump

HVAC Parts >>Air Conditioner Spare Parts >>Air Condition Installation >>Condensate Removal System  >>Air Conditioner Condensate Exit

Condensate Drain Pump

 

Condensate Drain Pump Type A

Condensate Drain Pump Condensate Drain Pump2 Condensate Drain Pump

Nice-looking after installation.

Condensate Drain Pump3

 

After use it,the trouble from condensate goes away!

Features:
1),Microsoft computer control with no mistake and it`s first to creat.
2),Shaded pole motor torqueforce is powerful and guarantee never block the pipe.
3),Exceptional exothern protective equipment with high safety performance.
4),Overlarge disrosopia impeller and the capability of pollution discharge is powerful.
5),Microsoft computer control system,wipe off the mechanical noise from pump.
6),The pump have the function of invented valve,never cause reverse current because of the circumfluence by drain fail.
7),Isolated heat preservation design0crust don`t have condensation of mositure and sweat.
8),Adopt fireproof material,and fire rating up to UL94V-0.
9),Ver low noise.When it working normally,you wouldn`t feel its existing.

 

Condensate Drain Pump Type B

Condensate Drain Pump Type A

Safety
-Before carrying out any operation on小a pump, make sure小a installation is
disconnected from the power supply
-The pump has been evaluated for use with water only.
-Risk of electronic shock This pump has not been investigated for use in
swimming pool or manne areas
-If thecord Is damaged.it mustt be replaced with a special ord or assemly
avaiable from the manufacturer or it’s service agent
-Do not run this pump try
-Always ensure the metal magnet in the float is facing upward .Always ensure
the reservoir is sitting flat and horizontal.
-The punP IS ideal for most working and living environments.It is not
recommended where the environments is city or particularly dusty
-Acceptable for indoor use only
-Non-submersible pump

Condensate Drain Pump

Condensate Drain Pump Type B1

Condensate Drain Pump Type B2

 

 

 Model:

model1

More knowledge:

     How to removal the condensates from the air conditioning?

Condensates (drops of water caused by warm, humid air passing over a
cold surface) are formed In sir conditioning, refrigeration and condensing
boiler units. There are 2 ways of removing them;
1. Evacuate the condensates by gravity, which means dealing with
technical and aesthetic problems (distant drainage outlet, not enough
fall, damage to walls and unsightly pipe work)
2. Instal a condensate removal pump (smaller dimensions. the appearance
of the installation is preserved for pearl spring series, simple and quick
to install for clear spring series, safer as equipped with alarm and non
return valve).

     What is a Condensate Drain Pump?

It is a system condensates gravity fall which consists
to be evacuated of a pump unit and a detection unit allowing
to a water drainage outlet where there is no gravity fall.

       This technology has 3 advantages:

1. It protects the appearance of the customer’s Installation (nounsightly pipework) 2. Easy, simple and safe to install
3. Reduction of the risk of bacterial contamination by waste water (no stagnation or back-flow of water due to non return valves)

 

HVAC Parts >>Air Conditioner Spare Parts >>Air Condition Installation >>Condensate Removal System  >>Air Conditioner Condensate Exit

Condensate Removal Pump

HVAC Parts >>Air Conditioner Spare Parts >>Air Condition Installation >>Condensate Removal System >>Condensate Removal Pump

condensate pump

 

Condensate Removal Pump Type A

Condensate Removal Pump Type B

Condensate Removal Pump

Condensate Removal Pump Type B2

Condensate Removal Pump Type B3

Condensate Removal Pump Type B4

Condensate Removal Pump Type B5

Condensate Removal Pump Type B6

Condensate Removal Pump Type B7

model2


 

Condensate Removal Pump Type B

Condensate Removal Pump

 

Condensate Removal Pump

Condensate Removal Pump is used for remove condensate water in inlaid type,ceiling suspended and disconnect-type air conditioners.

This type Condensate Removal Pump is a total system,for remove condensate water in inlaid type,ceiling suspended and disconnect-type air conditioners,which can`t be removed naturally.Its design has two parts: pump room/control equipment,water storage tank add on automatic switch. These two parts can be installed in air conditioners,or pump room/control equipment can be installed on ceiling ,which above the water storage tank within 1 meter.Floating control of water storage tank is seperated into three parts:start-up,cease and safety warming switch.Enclose: inlet pipe,clamp,cloth insertion sheet,exhaust pipe and drain pipe.

Condensate Removal Pump`s characteric:
1),Full rotation type;start up,cease,water-line spilled over safety warming switch(start-up warmer or turn off air conditioner.
2),Designed as two parts,used for easilly and quickly install.
3),Pump is auto-suction type,can be installed in air conditioner,or place in it above tank within 1 meter.
4),Water storage tank connects on13-17 mm wash port in air conditioner.
5),Max. flow: 14k/h(3.7US gallon).
6),Max.head:12m(39feet)
7),Operating range:6kl/h while head is 4m(1.6US Gallon/h while head is 13.1feet)
8),Used for air conditioner equipment,max is 10KW(30000BTU)(4KW used in wet areas).
9),Exhaust pipe enclose water storage tank.
10),Overheating auto poweroff protective device.
11),Design of pump exit used for 4x6mm(5/32 inch diameter of water pipe).
12)IP=20.
13)eNCLOSE:sELF-ABSORPTION WATER PIPE:1MX4MM(31/4 FEET X 5/32 inch inner diameter).Exhaust pipe:150MMX4MM(6INCHX5/32inch inner diameter) Drain pipe of air conditioner:75mmx13mm(3inchx1/2inch inner diamter)


More knowledge:

     How to removal the condensates from the air conditioning?

Condensates (drops of water caused by warm, humid air passing over a
cold surface) are formed In sir conditioning, refrigeration and condensing
boiler units. There are 2 ways of removing them;
1. Evacuate the condensates by gravity, which means dealing with
technical and aesthetic problems (distant drainage outlet, not enough
fall, damage to walls and unsightly pipe work)
2. Instal a condensate removal pump (smaller dimensions. the appearance
of the installation is preserved for pearl spring series, simple and quick
to install for clear spring series, safer as equipped with alarm and non
return valve).

     What is a Condensate Removal Pump?

It is a system condensates gravity fall which consists
to be evacuated of a pump unit and a detection unit allowing
to a water drainage outlet where there is no gravity fall.

       This technology has 3 advantages:

1. It protects the appearance of the customer’s Installation (nounsightly pipework) 2. Easy, simple and safe to install
3. Reduction of the risk of bacterial contamination by waste water (no stagnation or back-flow of water due to non return valves)

 

HVAC Parts >>Air Conditioner Spare Parts >>Air Condition Installation >>Condensate Removal System >>Condensate Removal Pump

Air Conditioner Condensate Exit

Condensate Exit For Air Conditioner Outdoor Unit

HVAC Parts >>Air Conditioner Spare Parts >>Air Condition Installation >>Condensate Removal System >>Air Conditioner Condensate Exit


Air Conditioner Condensate Exit — help you solve trouble of condensate water drip

Air Conditioner Condensate Exit

  • Description: Air Conditioner Condensate Exit
  • Used for drain condensate water from air conditioner
  • Place of Origin: Ningbo, China (Mainland),Made in China
  • Brand Name: Smartclima
  • Model Code : Same as description
  • Minimum Order Quantity:1000 Piece/order
  • Packaging Details: Carton box,210*195*230mm
  • Gross Weight per carton:
  • Delivery Time:One month after received customer confirmation
  • Supply Ability:100000 Piece per Month
Detailed Description on  Air Conditioner Condensate Exit      

Quick Detail

● Air Conditioner Condensate Exit;

● Used for drain condensate water from air conditioner;

● Help to solve the trouble of traditional condensate water drip;

● Design especially for split air conditioner outdoor unit;

● Anti-ageing,serve long years

Features

● Model Number:  Air Conditioner Condensate Exit;

● Specification: Φ 16mm

● Materials: Plastic

● Good elasticity to meet different outlet diameter of outdoor unit

● For drain out condensate water

Benefit&Advantage

● Suit different BTU air conditioner;

● Anti-ageing,serve long years;

● Top easy to install; Zero installation cost;

● Compared traditional steel drip tray,this Air Conditioner Condensate Exit is cheap on price,but safe when using , zero cost when install and low cost on delivery freight.

Benefits of Air Conditioner Condensate Exit

Application

For drain out condensate water at the bottom of A/C outdoor unit

Background & Remark

In summer,there are much consensate produced from air conditioner outdoor unit.Usually,people will omit this water,and the result is that the water will drop onto the materials or people on ground.Some house use consensate collection tray to collect water into the drain pipe dowm.But the steel tray is expensive and also is dangerious when it installed under outdoor unit.Now,you can usa this small tip to help you slove the trouble. It is made from plastic,anti-UV stability,you can use it many years.

 

Installation istructions for Plastic Air Conditioner Condensate Exit

Installation is very easy,just put it into the outlet  at the bottom of A/C outdoor unit as following 3 steps:

Air Conditioner Outdoor Unit Condensate Exit

1,put it into the bottom hole of outdoor unit.

Air Conditioner Outdoor Unit Condensate Exit

2,Then,put drain pipe onto the exit.If you like,you can use a clasp to fastern the pipe and exits.

Air Conditioner Outdoor Unit Condensate Exit

3,Put another exit of pipe into the drain system.

Condensate Exit For Air Conditioner Outdoor Unit

Ok,finish.the condensate water will flow into your drain system.


More models:

Air Conditioner Condensate Exit 1 Air Conditioner Condensate Exit 2Air Conditioner Condensate Exit 3Air Conditioner Condensate Exit 4Air Conditioner Condensate Exit 5Air Conditioner Condensate Exit 6Air Conditioner Condensate Exit 7Air Conditioner Condensate Exit 8Air Conditioner Condensate Exit 9

* More keywords: Condensate drip port ; Condensate drip tray;Air Conditioner Outdoor Unit drain port ;


HVAC Parts >>Air Conditioner Spare Parts >>Air Condition Installation >>Condensate Removal System >>Air Conditioner Condensate Exit

Condensate Collection Tray

HVAC Parts >>Air Conditioner Spare Parts >>Air Condition Installation >>Condensate Removal System >>Condensate Collection Tray

Condensate Collection Tray

Condensate Collection Tray

Condensate collection tray

Suits all air conditioner bracket ACB series.Supplied with all fixings.Surface is galvanized and powder painting.

Size:
790x390x30,
940x420x30,
1100x400x30,
800x400x30.

Condensation Collection Tray-1 Condensation Collection Tray-2 Condensation Collection Tray-3 Condensation Collection Tray-4 Condensation Collection Tray-5

 

HVAC Parts >>Air Conditioner Spare Parts >>Air Condition Installation >>Condensate Removal System >>Condensate Collection Tray

Air Conditioner Condensate Drain Pipe

HVAC Parts >>Air Conditioner Spare Parts >>Air Condition Installation >>Condensate Removal System >>Air Conditioner Condensate Drain Pipe

Air Conditioner Condensate Drain Pipe

There are some choices for Air Conditioner Condensate Drain Pipe.You can choose any one according to your situation.

                                                                                                                                                                                          

Air Conditioner Condensate  Drain Pipe-regulary

Air Conditioner Condensate Drain Pipe

Air Conditioner Condensate Drain Pipe

Description: 16/18mm diameter,and 50m/roll long,anti-UV,carton box as packing,Carton size:73.5*38.5*58cm,one roll per carton,6rolls/pack, 190packs/20″ container.

 

1.for discharging the condensed water generated by the air conditioning indoor unit to the oudoor.

2.duplex structures with inner charcoal are able to defend ultraviolet ray ,prevent drainpipe from being aged or cracked .durabillity is improved over 3 times than single one .

3.pass sunshine weather meter 3000 hours test .

4.high performance pe ensure excellent corrosion resistance .

5.joints are built 100CM apart .suitable for F14,F16,F18
6.50m/ROLL

                                                                                                                                                                                       

Air Conditioner Condensate Soft Drain Pipe

Air Conditioner Condensate Soft Pipe

Stannds temperature from -10 degree to 60 degree.Difference dimension is avaible.

                                                                                                                                                                                         

Air Conditioner Condensate PVC Drain Pipe

Air Conditioner Condensate PVC Pipe

Description: 16/25/32mm diameter,and 3m long.

Air Conditioner Condensate PVC Drain Pipe accessories

Air Conditioner Condensate PVC Pipe accessories

 

HVAC Parts >>Air Conditioner Spare Parts >>Air Condition Installation >>Condensate Removal System >>Air Conditioner Condensate Drain Pipe