logo

Brazed Plate Heat Exchanger

now browsing by category

 

BPHE B3-014 brazed plate heat exchanger

Home>>Refrigerating Parts & Heating Elements>>Heat Exchangers>>Brazed Plate Heat Exchanger,BPHE Heat Exchanger>>BPHE B3-014 brazed plate heat exchanger

BPHE B3-014 brazed plate heat exchanger

BPHE B3-014 brazed plate heat exchanger BPHE B3-014 brazed plate heat exchanger

 

BPHE B3-014 brazed plate heat exchanger is the ideal choice for air driers and chillers, heat pump, economizers, desuperheaters and can be used for numerous other applications. The heat exchanger is designed to combine high thermal efficiency with energy savings.
Capacity: 0.5 – 5 kW

 

Envelop thickness of fins A (MM )

Weight(KG)

Volume of one-side passage(L)

Effective working area(M 2 )

9+2.3N

0.5+0.05N

0.010(N-2)

0.014X(N-2)

 

Optional connections of Model B3-014

Type of connections

Model of connections

Screwless welded connection

H103/ H104/ H105/ H106/H107/ D116/ D118

Taper male thread connection

R104/R106

Straight male thread connection

W104/W106

Taper female thread connection

C104/C106

Straight female thread connection

N104/N106

Refer to the list of connections for detailed dimensions

 

Parameters of Model B3-014

Working area per plate

0.014(m 2 )

Designed pressure

1.0Mpa

3.0Mpa

4.5Mpa

Testing pressure

1.5Mpa

4.5Mpa

6.5Mpa

Working temperature

-160 BPHE B3-014 brazed plate heat exchanger 1 to 200BPHE B3-014 brazed plate heat exchanger 1

Max flowrate of water side

6 m 3 /h

Max plate assembly

60 PCS

Type of plate passage

D

Plate material

Stainless steel 316L

Mounting opinion

Bolts

Application

Wall-mounted Heater, Water Heater, Low Temperature Testing Equipment, Small-sized Refrigeration Equipment, etc.

         TypeNo. of platesConn. type
Q1/Q2
Conn. Size
Q1/Q2 [in]
Thread Q1/Q2
Int./Ext.
Conn. type
Q3/Q4
Conn. size
Q3/Q4 [in]
BPHE B3-01410    G3/4 inExternalSolder, ODF   3/4 in
BPHE B3-01414    G3/4 inExternalSolder, ODF   3/4 in
BPHE B3-01420    G3/4 inExternalSolder, ODF   3/4 in
BPHE B3-01426    G3/4 inExternalSolder, ODF   3/4 in
BPHE B3-01430    G3/4 inExternalSolder, ODF   3/4 in
BPHE B3-01436    G3/4 inExternalSolder, ODF   3/4 in
Brazed heat exchanger technology description
The Brazed heat exchanger is one of the most effective methods to transmit heat between the medium. The whole set of Brazed heat exchanger is composed by the ripple channel board, they combine together to form the complex Brazed heat exchanger channel. The cold and hot media assignment is completed through these channels. The cold and hot media is separated in both sides of the corrugated sheet, close as far as possible but not mixing; When they flow shoulder to shoulder, the quantity of heat is transmitted from one medium to another medium. The product concept based on modular as well as the parts that definitely can be customized, we always can find the most suitable solution for the application of each kind of heat exchanger.
Brazed heat exchanger structure principle
The Brazed heat exchanger on the whole is composed of a group of corrugated pipeline board between front and back baffles. The baffle groupware of Brazed heat exchanger is composed of seal board, seal ring and baffles. The Brazed heat exchanger connector type can be customized according to specific request of the market and the application domain. In the vacuum Brazed process, each contact point between the slab and the filling material (braze welding solder) can form a weld point. Using such a design, it can make the heat exchanger which is composed of two different channels or the return route. The seal board is used in the crevice between seal baffle and the first and last channel board. The quantity of baffles is decided by the type, size and pressure rank and so on. Some are loaded with the seal ring, used in the crevice between the sealing channel board and the baffle. Some seal rings and the baffle as well as the first or the last channel boards combine a whole.
Brazed heat exchanger passage type
In a Brazed heat exchanger, the slab number usually reaches several dozens pieces. The liquid flow of Brazed heat exchanger between boards can be combined neatly according to the concrete service condition. Generally there are all kinds of combination of single-flow and multi-flow. If both sides medium are even single-flow, it is available to make one side medium as the single-flow and the other side medium as the double-flow, and also both sides medium as the different multi-flow combination. The standard combination of Halley Brazed heat exchanger is that both hot and cold sides are single-flow, and can be customized to be multi-flow heat exchanger as per the customer request.
Home>>Refrigerating Parts & Heating Elements>>Heat Exchangers>>Brazed Plate Heat Exchanger,BPHE Heat Exchanger>>BPHE B3-014 brazed plate heat exchanger

BPHE B3-095 brazed plate heat exchanger

Home>>Refrigerating Parts & Heating Elements>>Heat Exchangers>>Brazed Plate Heat Exchanger,BPHE Heat Exchanger>>  BPHE B3-095 brazed plate heat exchanger

BPHE B3-095 brazed plate heat exchanger

BPHE B3-095 brazed plate heat exchanger Brazed Plate Heat Exchanger 7a

BPHE B3-095 brazed plate heat exchanger is the ideal choice for chillers, heat pumps, economizers, desuperheaters and can be used for numerous other applications. The heat exchanger is designed to combine high thermal efficiency with energy savings.
Capacity: 30 – 200 kW

Envelop thickness of fins A
(MM )

Weight(KG)

Volume of one-side passage(L)

Effective working area(M 2 )

11+2.8N

6+0.39N

0.125(N-2)

0.095X(N-2)

 

Optional connections of Model B3-095

Type of connections

Model of connections

Screwless welded connection

H407/ H410/ H411/ H413/ 414/ H415/ H520/ H521/D116/D428/D432/D442

Taper male thread connection

R414/R520

Straight male thread connection

W414/W520

Taper female thread connection

C404/C406/C410/C514

Straight female thread connection

N404/N406/N410/N512/ N514/ N520

Clipped connection

J414/J520

Flanged connection

DN54 single flange/ DN54 double flanges

Refer to the list of connections for detailed dimensions

 

Parameters of Model B3-095

Working area per plate

0.095(m 2 )

Designed pressure

1.0Mpa

3.0Mpa

4.5Mpa

Testing pressure

1.5Mpa

4.5Mpa

6.5Mpa

Working temperature

-160 BPHE B3-095 brazed plate heat exchanger 3 to 200 BPHE B3-095 brazed plate heat exchanger 4

Max flowrate of water side

45 m 3 /h

Max plate assembly

150 PCS

Type of plate passage

D, X, H

Plate material

Stainless steel 304, 316L

Mounting opinion

Bolts, Footing, Temperature

Application

Heat pumps, central air-conditioning, waste heat reclaim, refrigeration equipment, industrial water coolers, oil coolers, etc.
TypeNo. of plates

Conn. type
Q1/Q2

Conn. size Q1/Q2 [in]Thread Q1/Q2
Int./Ext.
Conn. type
Q3/Q4
Conn. size
Q3/Q4 [in]
PHE B3-09544G2ExternalSolder, ODF2 1/8 in
PHE B3-09550G2ExternalSolder, ODF2 1/8 in
PHE B3-09560G2ExternalSolder, ODF2 1/8 in
PHE B3-09570G2ExternalSolder, ODF2 1/8 in
PHE B3-09580G2ExternalSolder, ODF2 1/8 in
PHE B3-09590G2ExternalSolder, ODF2 1/8 in
PHE B3-095100G2ExternalSolder, ODF2 1/8 in
PHE B3-095110G2ExternalSolder, ODF2 1/8 in
PHE B3-095120G2ExternalSolder, ODF2 1/8 in
PHE B3-095130G2ExternalSolder, ODF2 1/8 in
Brazed heat exchanger technology description
The Brazed heat exchanger is one of the most effective methods to transmit heat between the medium. The whole set of Brazed heat exchanger is composed by the ripple channel board, they combine together to form the complex Brazed heat exchanger channel. The cold and hot media assignment is completed through these channels. The cold and hot media is separated in both sides of the corrugated sheet, close as far as possible but not mixing; When they flow shoulder to shoulder, the quantity of heat is transmitted from one medium to another medium. The product concept based on modular as well as the parts that definitely can be customized, we always can find the most suitable solution for the application of each kind of heat exchanger.Brazed heat exchanger structure principle
The Brazed heat exchanger on the whole is composed of a group of corrugated pipeline board between front and back baffles. The baffle groupware of Brazed heat exchanger is composed of seal board, seal ring and baffles. The Brazed heat exchanger connector type can be customized according to specific request of the market and the application domain. In the vacuum Brazed process, each contact point between the slab and the filling material (braze welding solder) can form a weld point. Using such a design, it can make the heat exchanger which is composed of two different channels or the return route. The seal board is used in the crevice between seal baffle and the first and last channel board. The quantity of baffles is decided by the type, size and pressure rank and so on. Some are loaded with the seal ring, used in the crevice between the sealing channel board and the baffle. Some seal rings and the baffle as well as the first or the last channel boards combine a whole.Brazed heat exchanger passage type
In a Brazed heat exchanger, the slab number usually reaches several dozens pieces. The liquid flow of Brazed heat exchanger between boards can be combined neatly according to the concrete service condition. Generally there are all kinds of combination of single-flow and multi-flow. If both sides medium are even single-flow, it is available to make one side medium as the single-flow and the other side medium as the double-flow, and also both sides medium as the different multi-flow combination. The standard combination of Halley Brazed heat exchanger is that both hot and cold sides are single-flow, and can be customized to be multi-flow heat exchanger as per the customer request.
Home>>Refrigerating Parts & Heating Elements>>Heat Exchangers>>Brazed Plate Heat Exchanger,BPHE Heat Exchanger>>  BPHE B3-095 brazed plate heat exchanger

BPHE B3-020 brazed plate heat exchanger

Home>>Refrigerating Parts & Heating Elements>>Heat Exchangers>>Brazed Plate Heat Exchanger,BPHE Heat Exchanger>>  BPHE B3-020 brazed plate heat exchanger

BPHE B3-020 brazed plate heat exchanger

BPHE B3-020 brazed plate heat exchanger Brazed Plate Heat Exchanger 6a

 

Refrigerants: R407C, R22, R404A, R410A, R134a
Design temperature: ¨C196 – +200ºC/¨C320 – +392ºF
Standard design pressure: 30 bar/435 psi
Test pressure: 45 bar/653 psi
Standard plate material: AISI 316L
Brazing material: Copper
Other configurations available on request

Envelop thickness of fins A (MM )

Weight(KG)

Volume of one-side passage(L)

Effective working area(M 2 )

9+2.3N

1.0+0.08N

0.018(N-2)

0.02X(N-2)

 

Optional connections of Model B3-020

Type of connections

Model of connections

Screwless welded connection

H103/ H104/ H105/ H106/ H107/ D116/D118

Taper male thread connection

R104/R106

Straight male thread connection

W104/W106

Taper female thread connection

C104/C106

Straight female thread connection

N104/N106

Refer to the list of connections for detailed dimensions

 

Parameters of Model B3-020

Working area per plate

0.02(m 2 )

Designed pressure

1.0Mpa

3.0Mpa

4.5Mpa

Testing pressure

1.5Mpa

4.5Mpa

6.5Mpa

Working temperature

-160 BPHE B3-020 brazed plate heat exchanger 5 to 200 BPHE B3-020 brazed plate heat exchanger 5

Max flowrate of water side

6 m 3 /h

Max plate assembly

80 PCS

Type of plate passage

D, X, H

Plate material

Stainless steel 304, 316L

Brazed heat exchanger technology description
The Brazed heat exchanger is one of the most effective methods to transmit heat between the medium. The whole set of Brazed heat exchanger is composed by the ripple channel board, they combine together to form the complex Brazed heat exchanger channel. The cold and hot media assignment is completed through these channels. The cold and hot media is separated in both sides of the corrugated sheet, close as far as possible but not mixing; When they flow shoulder to shoulder, the quantity of heat is transmitted from one medium to another medium. The product concept based on modular as well as the parts that definitely can be customized, we always can find the most suitable solution for the application of each kind of heat exchanger.

Brazed heat exchanger structure principle
The Brazed heat exchanger on the whole is composed of a group of corrugated pipeline board between front and back baffles. The baffle groupware of Brazed heat exchanger is composed of seal board, seal ring and baffles. The Brazed heat exchanger connector type can be customized according to specific request of the market and the application domain. In the vacuum Brazed process, each contact point between the slab and the filling material (braze welding solder) can form a weld point. Using such a design, it can make the heat exchanger which is composed of two different channels or the return route. The seal board is used in the crevice between seal baffle and the first and last channel board. The quantity of baffles is decided by the type, size and pressure rank and so on. Some are loaded with the seal ring, used in the crevice between the sealing channel board and the baffle. Some seal rings and the baffle as well as the first or the last channel boards combine a whole.

Brazed heat exchanger passage type
In a Brazed heat exchanger, the slab number usually reaches several dozens pieces. The liquid flow of Brazed heat exchanger between boards can be combined neatly according to the concrete service condition. Generally there are all kinds of combination of single-flow and multi-flow. If both sides medium are even single-flow, it is available to make one side medium as the single-flow and the other side medium as the double-flow, and also both sides medium as the different multi-flow combination. The standard combination of Halley Brazed heat exchanger is that both hot and cold sides are single-flow, and can be customized to be multi-flow heat exchanger as per the customer request.

 

Home>>Refrigerating Parts & Heating Elements>>Heat Exchangers>>Brazed Plate Heat Exchanger,BPHE Heat Exchanger>>  BPHE B3-020 brazed plate heat exchanger

BPHE B3-026 Brazed plate heat exchanger

Home>>Refrigerating Parts & Heating Elements>>Heat Exchangers>>Brazed Plate Heat Exchanger,BPHE Heat Exchanger>>  BPHE B3-026 Brazed plate heat exchanger

BPHE B3-026 Brazed plate heat exchanger

BPHE B3-026 Brazed plate heat exchanger Brazed Plate Heat Exchanger 5a

 

Refrigerants: R407C, R22, R404A, R410A, R134a
Design temperature: ¨C196 – +200ºC/¨C320 – +392ºF
Standard design pressure: 30 bar/435 psi
Test pressure: 45 bar/653 psi
Standard plate material: AISI 316L
Brazing material: Copper
Other configurations available on request

 

Envelop thickness of fins A (MM )

Weight(KG)

Volume of one-side passage(L)

Effective working area(M 2 )

9+2.4N

1.1+0.115N

0.025(N-2)

0.026X(N-2)

 

Optional connections of Model B3-026

Type of connections

Model of connections

Screwless welded connection

H103/ H104/ H105/ H106/ H207/ H210/ H211/
H212/ 214/ H313/D116/D118/D225/S313

Taper male thread connection

R104/R106/ R210/R312/R314

Straight male thread connection

W104/W106/W210/W312

Taper female thread connection

C104/C106/C206/C210

Straight female thread connection

N104/N106/N206/N210

Refer to the list of connections for detailed dimensions

 

Parameters of Model B3-026

Working area per plate

0.026(m 2 )

Designed pressure

1.0Mpa

3.0Mpa

4.5Mpa

Testing pressure

1.5Mpa

4.5Mpa

6.5Mpa

Working temperature

-160BPHE B3-026 Brazed plate heat exchanger 7 to  200 BPHE B3-026 Brazed plate heat exchanger 7

Max flowrate of water side

18 m 3 /h

Max plate assembly

120 PCS

Type of plate passage

D, X, H

Plate material

Stainless steel 304, 316L

Mounting opinion

Bolts, Footing, Temperature

Application

Heat pumps, central air-conditioning, waste heat reclaim, refrigeration equipment, industrial water coolers, oil coolers, etc.

Brazed heat exchanger technology description
The Brazed heat exchanger is one of the most effective methods to transmit heat between the medium. The whole set of Brazed heat exchanger is composed by the ripple channel board, they combine together to form the complex Brazed heat exchanger channel. The cold and hot media assignment is completed through these channels. The cold and hot media is separated in both sides of the corrugated sheet, close as far as possible but not mixing; When they flow shoulder to shoulder, the quantity of heat is transmitted from one medium to another medium. The product concept based on modular as well as the parts that definitely can be customized, we always can find the most suitable solution for the application of each kind of heat exchanger.

Brazed heat exchanger structure principle
The Brazed heat exchanger on the whole is composed of a group of corrugated pipeline board between front and back baffles. The baffle groupware of Brazed heat exchanger is composed of seal board, seal ring and baffles. The Brazed heat exchanger connector type can be customized according to specific request of the market and the application domain. In the vacuum Brazed process, each contact point between the slab and the filling material (braze welding solder) can form a weld point. Using such a design, it can make the heat exchanger which is composed of two different channels or the return route. The seal board is used in the crevice between seal baffle and the first and last channel board. The quantity of baffles is decided by the type, size and pressure rank and so on. Some are loaded with the seal ring, used in the crevice between the sealing channel board and the baffle. Some seal rings and the baffle as well as the first or the last channel boards combine a whole.

Brazed heat exchanger passage type
In a Brazed heat exchanger, the slab number usually reaches several dozens pieces. The liquid flow of Brazed heat exchanger between boards can be combined neatly according to the concrete service condition. Generally there are all kinds of combination of single-flow and multi-flow. If both sides medium are even single-flow, it is available to make one side medium as the single-flow and the other side medium as the double-flow, and also both sides medium as the different multi-flow combination. The standard combination of Halley Brazed heat exchanger is that both hot and cold sides are single-flow, and can be customized to be multi-flow heat exchanger as per the customer request.

 

Home>>Refrigerating Parts & Heating Elements>>Heat Exchangers>>Brazed Plate Heat Exchanger,BPHE Heat Exchanger>>  BPHE B3-026 Brazed plate heat exchanger

BPHE B3-190 Brazed plate heat exchanger

Home>>Refrigerating Parts & Heating Elements>>Heat Exchangers>>Brazed Plate Heat Exchanger,BPHE Heat Exchanger>>  BPHE B3-190 Brazed plate heat exchanger

BPHE B3-190 Brazed plate heat exchanger

BPHE B3-190 Brazed plate heat exchanger Brazed Plate Heat Exchanger 4a

 

Refrigerants: R407C, R22, R404A, R410A, R134a
Design temperature: ¨C196 – +200ºC/¨C320 – +392ºF
Standard design pressure: 30 bar/435 psi
Test pressure: 45 bar/653 psi
Standard plate material: AISI 316L
Brazing material: Copper
Other configurations available on request

Envelop thickness of fins A (MM)

Weight(KG)

Volume of one-side passage(L)

Effective working area(M 2 )

13+2.65N

10+0.51N

0.217(N-2)

0.19X(N-2)

 

Optional connections of Model B3-190

Type of connections

Model of connections

Screwless welded connection

S407/ S411/ S413/ S414/ S520/ S521/ S923/ S925/S930/S931/SD442/SD966/SD990/SD998

Taper male thread connection

SR520

Straight male thread connection

SW414/SW520/SW924/SW930

Straight female thread connection

SN404

Clipped connection

SJ924/SJ930

Flanged connection

DN100 single flange/ DN100 double flanges

Refer to the list of connections for detailed dimensions

 

Parameters of Model B3-190

Working area per plate

0.19(m 2 )

Designed pressure

1.0Mpa

3.0Mpa

4.5Mpa

Testing pressure

1.5Mpa

4.5Mpa

6.5Mpa

Working temperature

-160 BPHE B3-190 Brazed plate heat exchanger 9 to  200 BPHE B3-190 Brazed plate heat exchanger 9

Max flowrate of water side

140 m 3 /h

Max plate assembly

320 PCS

Type of plate passage

D, X, H

Plate material

Stainless steel 316L

Mounting opinion

Bolts, Footing, Lug, Temperature

Application

Heat pumps, central air-conditioning, waste heat reclaim, refrigeration equipment, industrial water coolers, oil coolers, etc.

Brazed heat exchanger technology description
The Brazed heat exchanger is one of the most effective methods to transmit heat between the medium. The whole set of Brazed heat exchanger is composed by the ripple channel board, they combine together to form the complex Brazed heat exchanger channel. The cold and hot media assignment is completed through these channels. The cold and hot media is separated in both sides of the corrugated sheet, close as far as possible but not mixing; When they flow shoulder to shoulder, the quantity of heat is transmitted from one medium to another medium. The product concept based on modular as well as the parts that definitely can be customized, we always can find the most suitable solution for the application of each kind of heat exchanger.

Brazed heat exchanger structure principle
The Brazed heat exchanger on the whole is composed of a group of corrugated pipeline board between front and back baffles. The baffle groupware of Brazed heat exchanger is composed of seal board, seal ring and baffles. The Brazed heat exchanger connector type can be customized according to specific request of the market and the application domain. In the vacuum Brazed process, each contact point between the slab and the filling material (braze welding solder) can form a weld point. Using such a design, it can make the heat exchanger which is composed of two different channels or the return route. The seal board is used in the crevice between seal baffle and the first and last channel board. The quantity of baffles is decided by the type, size and pressure rank and so on. Some are loaded with the seal ring, used in the crevice between the sealing channel board and the baffle. Some seal rings and the baffle as well as the first or the last channel boards combine a whole.

Brazed heat exchanger passage type
In a Brazed heat exchanger, the slab number usually reaches several dozens pieces. The liquid flow of Brazed heat exchanger between boards can be combined neatly according to the concrete service condition. Generally there are all kinds of combination of single-flow and multi-flow. If both sides medium are even single-flow, it is available to make one side medium as the single-flow and the other side medium as the double-flow, and also both sides medium as the different multi-flow combination. The standard combination of Halley Brazed heat exchanger is that both hot and cold sides are single-flow, and can be customized to be multi-flow heat exchanger as per the customer request.

 

Home>>Refrigerating Parts & Heating Elements>>Heat Exchangers>>Brazed Plate Heat Exchanger,BPHE Heat Exchanger>>  BPHE B3-190 Brazed plate heat exchanger

BPHE B3-300 brazed plate heat exchanger

Home>>Refrigerating Parts & Heating Elements>>Heat Exchangers>>Brazed Plate Heat Exchanger,BPHE Heat Exchanger>> BPHE B3-300 brazed plate heat exchanger

BPHE B3-300 brazed plate heat exchanger

BPHE B3-300 brazed plate heat exchanger Brazed Plate Heat Exchanger 3a

 

Refrigerants: R407C, R22, R404A, R410A, R134a
Design temperature: ¨C196 – +200ºC/¨C320 – +392ºF
Standard design pressure: 30 bar/435 psi
Test pressure: 45 bar/653 psi
Standard plate material: AISI 316L
Brazing material: Copper
Other configurations available on request

Envelop thickness of fins A (MM )

Weight(KG)

Volume of one-side passage(L)

Effective working area(M 2 )

16+2.62N

57+1.26N

0.3(N-2)

0.3X(N-2)

 

Optional connections of Model B3-300

Type of connections

Model of connections

Screwless welded connection

S407/ S411/ S413/ S414/ S520/ S521/ S923/ S925/S930/S931/S040/S041/SD442/SD966/SD990/SD998

Taper male thread connection

SR520

Straight male thread connection

SW414/SW520/SW924/SW930/SW040

Straight female thread connection

SN404

Clipped connection

SJ924/SJ930

Flanged connection

DN105 single flange

Refer to the list of connections for detailed dimensions

 

Parameters of Model B3-300

Working area per plate

0.3(m 2 )

Designed pressure

1.0Mpa

3.0Mpa

4.5Mpa

Testing pressure

1.5Mpa

4.5Mpa

6.5Mpa

Working temperature

-160 BPHE B3-300 brazed plate heat exchanger 11 to 200 BPHE B3-300 brazed plate heat exchanger 11

Max flowrate of water side

160 m 3 /h

Max plate assembly

320 PCS

Type of plate passage

D

Plate material

Stainless steel 316L

Mounting opinion

Footing, Lug, Temperature detection tube

Application

Heat pumps, central air-conditioning, waste heat reclaim, refrigeration equipment, industrial water coolers, oil coolers, etc.

Brazed heat exchanger technology description
The Brazed heat exchanger is one of the most effective methods to transmit heat between the medium. The whole set of Brazed heat exchanger is composed by the ripple channel board, they combine together to form the complex Brazed heat exchanger channel. The cold and hot media assignment is completed through these channels. The cold and hot media is separated in both sides of the corrugated sheet, close as far as possible but not mixing; When they flow shoulder to shoulder, the quantity of heat is transmitted from one medium to another medium. The product concept based on modular as well as the parts that definitely can be customized, we always can find the most suitable solution for the application of each kind of heat exchanger.

Brazed heat exchanger structure principle
The Brazed heat exchanger on the whole is composed of a group of corrugated pipeline board between front and back baffles. The baffle groupware of Brazed heat exchanger is composed of seal board, seal ring and baffles. The Brazed heat exchanger connector type can be customized according to specific request of the market and the application domain. In the vacuum Brazed process, each contact point between the slab and the filling material (braze welding solder) can form a weld point. Using such a design, it can make the heat exchanger which is composed of two different channels or the return route. The seal board is used in the crevice between seal baffle and the first and last channel board. The quantity of baffles is decided by the type, size and pressure rank and so on. Some are loaded with the seal ring, used in the crevice between the sealing channel board and the baffle. Some seal rings and the baffle as well as the first or the last channel boards combine a whole.

Brazed heat exchanger passage type
In a Brazed heat exchanger, the slab number usually reaches several dozens pieces. The liquid flow of Brazed heat exchanger between boards can be combined neatly according to the concrete service condition. Generally there are all kinds of combination of single-flow and multi-flow. If both sides medium are even single-flow, it is available to make one side medium as the single-flow and the other side medium as the double-flow, and also both sides medium as the different multi-flow combination. The standard combination of Halley Brazed heat exchanger is that both hot and cold sides are single-flow, and can be customized to be multi-flow heat exchanger as per the customer request.

 

Home>>Refrigerating Parts & Heating Elements>>Heat Exchangers>>Brazed Plate Heat Exchanger,BPHE Heat Exchanger>> BPHE B3-300 brazed plate heat exchanger

BPHE B3-052 Brazed plate heat exchanger

Home>>Refrigerating Parts & Heating Elements>>Heat Exchangers>>Brazed Plate Heat Exchanger,BPHE Heat Exchanger>>  BPHE B3-052 Brazed plate heat exchanger

BPHE B3-052 Brazed plate heat exchanger

BPHE B3-052 Brazed plate heat exchanger BPHE B3-052 Brazed plate heat exchanger

 

BPHE B3-052 Brazed plate heat exchanger

Refrigerants: R407C, R22, R404A, R410A, R134a
Design temperature: ¨C196 – +200ºC/¨C320 – +392ºF
Standard design pressure: 30 bar/435 psi
Test pressure: 45 bar/653 psi
Standard plate material: AISI 316L
Brazing material: Copper
Other configurations available on request

Envelop thickness of fins (MM )

Weight(KG)

Volume of one-side passage(L)

Effective working area(M 2 )

9+2.45N

1.9+0.2N

0.047 (N-2)

0.05X(N-2)

 

Optional connections of Model B3-052

Type of connections

Model of connections

Screwless welded connection

H103/ H104/ H105/ H106/ H207/ H210/ H211/H212/ 214/ H313/D116/D118/D225/S313

Taper male thread connection

R104/R106/ R210/R312/R314

Straight male thread connection

W104/W106/W210/W312

Taper female thread connection

C104/C106/C206/C210

Straight female thread connection

N104/N106/N206/N210

Refer to the list of connections for detailed dimensions

 

Parameters of Model B3-052

Working area per plate

0.05 (m 2 )

Designed pressure

1.0Mpa

3.0Mpa

4.5Mpa

Testing pressure

1.5Mpa

4.5Mpa

6.5Mpa

Working temperature

-160 BPHE B3-052 Brazed plate heat exchanger 13 to 200 BPHE B3-052 Brazed plate heat exchanger 13

Max flowrate of water side

18 m 3 /h

Max plate assembly

120 PCS

Type of plate passage

D, X, H

Plate material

Stainless steel 304, 316L

Mounting opinion

Bolts, Footing, Temperature

Application

Heat pumps, central air-conditioning, waste heat reclaim, refrigeration equipment, industrial water coolers, oil coolers, etc.

Brazed heat exchanger technology description
The Brazed heat exchanger is one of the most effective methods to transmit heat between the medium. The whole set of Brazed heat exchanger is composed by the ripple channel board, they combine together to form the complex Brazed heat exchanger channel. The cold and hot media assignment is completed through these channels. The cold and hot media is separated in both sides of the corrugated sheet, close as far as possible but not mixing; When they flow shoulder to shoulder, the quantity of heat is transmitted from one medium to another medium. The product concept based on modular as well as the parts that definitely can be customized, we always can find the most suitable solution for the application of each kind of heat exchanger.

Brazed heat exchanger structure principle
The Brazed heat exchanger on the whole is composed of a group of corrugated pipeline board between front and back baffles. The baffle groupware of Brazed heat exchanger is composed of seal board, seal ring and baffles. The Brazed heat exchanger connector type can be customized according to specific request of the market and the application domain. In the vacuum Brazed process, each contact point between the slab and the filling material (braze welding solder) can form a weld point. Using such a design, it can make the heat exchanger which is composed of two different channels or the return route. The seal board is used in the crevice between seal baffle and the first and last channel board. The quantity of baffles is decided by the type, size and pressure rank and so on. Some are loaded with the seal ring, used in the crevice between the sealing channel board and the baffle. Some seal rings and the baffle as well as the first or the last channel boards combine a whole.

Brazed heat exchanger passage type
In a Brazed heat exchanger, the slab number usually reaches several dozens pieces. The liquid flow of Brazed heat exchanger between boards can be combined neatly according to the concrete service condition. Generally there are all kinds of combination of single-flow and multi-flow. If both sides medium are even single-flow, it is available to make one side medium as the single-flow and the other side medium as the double-flow, and also both sides medium as the different multi-flow combination. The standard combination of Halley Brazed heat exchanger is that both hot and cold sides are single-flow, and can be customized to be multi-flow heat exchanger as per the customer request.

 

Home>>Refrigerating Parts & Heating Elements>>Heat Exchangers>>Brazed Plate Heat Exchanger,BPHE Heat Exchanger>>  BPHE B3-052 Brazed plate heat exchanger

BPHE B3-015 Brazed Plate Heat Exchanger

Home>>Refrigerating Parts & Heating Elements>>Heat Exchangers>>Brazed Plate Heat Exchanger,BPHE Heat Exchanger>> BPHE B3-015 Brazed Plate Heat Exchanger

BPHE B3-015 Brazed Plate Heat Exchanger

BPHE B3-015 Brazed Plate Heat ExchangerBPHE B3-015 Brazed Plate Heat Exchanger

 

Refrigerants: R407C, R22, R404A, R410A, R134a
Design temperature: ¨C196 – +200ºC/¨C320 – +392ºF
Standard design pressure: 30 bar/435 psi
Test pressure: 45 bar/653 psi
Standard plate material: AISI 316L
Brazing material: Copper
Other configurations available on request

Envelop thickness of fins A (MM )

Weight(KG)

Volume of one-side passage(L)

Effective working area(M 2 )

9+2.3N

0.4+0.04N

0.010(N-2)

0.015X(N-2)

 

Optional connections of Model B3-015

Type of connections

Model of connections

Taper male thread connection

RM104S/RM106S/R2102

Refer to the list of connections for detailed dimensions

 

Parameters of Model B3-015

Working area per plate

0.015(m 2 )

Designed pressure

1.0Mpa

3.0Mpa

Testing pressure

1.5Mpa

4.5Mpa

Working temperature

-160BPHE B3-015 Brazed Plate Heat Exchanger 15 to 200BPHE B3-015 Brazed Plate Heat Exchanger 16

Max flowrate of water side

6 m 3 /h

Max plate assembly

80 PCS

Type of plate passage

D

Plate material

Stainless steel 304, 316L

Mounting opinion

Bolts

Application

Wall-mounted Heater, Water Heater, Low Temperature Testing Equipment, Small-sized Refrigeration Equipment, etc.

Brazed heat exchanger technology description
The Brazed heat exchanger is one of the most effective methods to transmit heat between the medium. The whole set of Brazed heat exchanger is composed by the ripple channel board, they combine together to form the complex Brazed heat exchanger channel. The cold and hot media assignment is completed through these channels. The cold and hot media is separated in both sides of the corrugated sheet, close as far as possible but not mixing; When they flow shoulder to shoulder, the quantity of heat is transmitted from one medium to another medium. The product concept based on modular as well as the parts that definitely can be customized, we always can find the most suitable solution for the application of each kind of heat exchanger.Brazed heat exchanger structure principle
The Brazed heat exchanger on the whole is composed of a group of corrugated pipeline board between front and back baffles. The baffle groupware of Brazed heat exchanger is composed of seal board, seal ring and baffles. The Brazed heat exchanger connector type can be customized according to specific request of the market and the application domain. In the vacuum Brazed process, each contact point between the slab and the filling material (braze welding solder) can form a weld point. Using such a design, it can make the heat exchanger which is composed of two different channels or the return route. The seal board is used in the crevice between seal baffle and the first and last channel board. The quantity of baffles is decided by the type, size and pressure rank and so on. Some are loaded with the seal ring, used in the crevice between the sealing channel board and the baffle. Some seal rings and the baffle as well as the first or the last channel boards combine a whole.
Brazed heat exchanger passage type
In a Brazed heat exchanger, the slab number usually reaches several dozens pieces. The liquid flow of Brazed heat exchanger between boards can be combined neatly according to the concrete service condition. Generally there are all kinds of combination of single-flow and multi-flow. If both sides medium are even single-flow, it is available to make one side medium as the single-flow and the other side medium as the double-flow, and also both sides medium as the different multi-flow combination. The standard combination of Halley Brazed heat exchanger is that both hot and cold sides are single-flow, and can be customized to be multi-flow heat exchanger as per the customer request.

 

Home>>Refrigerating Parts & Heating Elements>>Heat Exchangers>>Brazed Plate Heat Exchanger,BPHE Heat Exchanger>> BPHE B3-015 Brazed Plate Heat Exchanger