FN R134a Compressor
|
Model |
Displ.
(cm3) |
Motor
Type |
Cooling |
Capacity
(W) |
Input Power
(W) |
Rated Current
(A) |
COP
(W/W) |
VOL/FRE
V/Hz |
|
FN43H |
4.30 |
RSIR |
S |
120 |
100 |
0.85 |
1.20 |
220/50 |
|
FN57H |
5.70 |
RSIR |
S |
138 |
114 |
0.90 |
1.22 |
220/50 |
|
FN66H |
6.60 |
RSIR |
S |
165 |
135 |
1.15 |
1.23 |
220/50 |
|
FN77H |
7.70 |
RSIR |
S |
190 |
154 |
1.30 |
1.24 |
220/50 |
|
FN91H |
9.10 |
RSIR |
S/F |
212 |
180 |
1.40 |
1.26 |
220/50 |
|
FN110H |
11.00 |
RSIR |
F |
284 |
230 |
1.60 |
1.23 |
220/50 |
|
Test Conditions:
1,Evaporating Temp.= -23.3degree (-10F)
2,Ambient Temp.=32.2degree(90F)
3,Condensing Temp.=54.4degree(130F)
4,Suction Temp.=32.2degree(90F)
5,Sub-cooling Temp.=32.2degree(90F)
|
Conversion Table:
1. 1watt=3.41BTU/h
2. 1watt=0.86Kcal/h
3.1Kcal/h=3.97BTU/h |
|
Tolerance of performance data:
(1)Capacity>/=95%
(2)Input Power</=115%
(3)Current</=110%
(4)COP>/=93% |
Cooling Type:
S--Static Cooling
F--Fan Cooling
H:R134a Refrigerant
L:LBP |
|
The compressor is the same with refrigeration implement which usually include refrigerator, refrigeration deepfreeze, kitchen refrigeration, display case, revelation tank, dehumidify appliance etc. The main feature: light compact, high efficiency, good reliability, low noise vibration. |
|